Abstract

Background. Redo cardiac surgery is considered high-risk surgery as accidental injury to the aorta, the innominate vein, the ventricles and the atria is a possibility. Such accidental injury occurs when the cardiac chamber is adherent to the undersurface of the sternum. Closure of pericardium at the time of primary surgery can prevent adherence of cardiac chambers to the sternum, but may increase the risk of tamponade. This study aimed to show that covering heart with a pedicled pericardial fat pad not only serves the purpose of cover but also avoids the adverse haemodynamic effects of primary pericardial closure.

Methods. Forty patients undergoing elective cardiac surgery were randomised into two groups depending on the way pericardium was managed. Both techniques were already in routine use in our unit and in other units around the country. One method is to leave the pericardium widely open, the other is to loosely oppose the pericardial fat pad over the surface of the aorta and right ventricle. Twenty-three patients had a pedicled pericardial fat pad covering the heart: Closure Group. Seventeen patients had no pericardial fat pad cover over the heart: Open Group. A haemostasis clip was used as a radio-opaque marker over the epicardium in both groups. Post-operation heart rate, central venous pressure, pulmonary artery diastolic pressure, mean arterial pressure and cardiac index were measured and recorded 1, 3 and 8h after surgery. The distance between the haemoclip and the posterior table of the sternum was measured at 6 days and 6 months post-operation. Haemodynamic parameters and the retrosternal space depth were compared between the two groups.

Results. There were no important differences in haemodynamic parameters between the two groups. Post-operative lateral chest Roentgenograms showed that the distance between epicardial surface and the posterior table of sternum was larger in the Closure Group compared to Open Group on post-operative day 6, 17.5±1.0mm versus 13.4±1.3mm (P=0.0013) and 6 months later, 12.3±0.8mm versus 6.0±1.2mm (P<0.001). There was no mortality in either group.

Conclusion. Pedicled pericardial fat pad cover is a good alternative to primary pericardial closure as there are no adverse haemodynamic effects in early post-operative period and the long-term benefit of protection of heart at the time of re-sternotomy can be expected.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Redo cardiac surgery, Pericardial closure, Cardiac tamponade


Mappa


© 2004  Australasian Society of Cardiac and Thoracic Surgeons and the Cardiac Society of Australia and New Zealand. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 13 - N° 1

P. 52-55 - marzo 2004 Ritorno al numero
Articolo precedente Articolo precedente
  • Allograft Aortic Valve Replacement in the Adult: A Review
  • Cheng-Hon Yap, Michael Yii
| Articolo seguente Articolo seguente
  • Viable Extracardiac Total Right Heart Bypass: Technical Considerations and Mid-term Results
  • Ujjwal K Chowdhury, Shyam S Kothari, Anita Saxena, Akhil Govil, Ganapathy Subramaniam, Balram Airan

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.