Abbonarsi

Angiographic and three-dimensional intravascular ultrasound analysis of combined intracoronary beta radiation and self-expanding stent implantation in human coronary arteries - 26/08/11

Doi : 10.1016/j.amjcard.2004.07.106 
Valeria Ferrero, MD a, , Flavio Ribichini, MD a, Guy R. Heyndrickx, MD, PhD b, Bernard De Bruyne, MD, PhD b, Marleen Piessens, PhD c, Stéphane Carlier, MD, PhD d, Martin Büchi, MD e, Giuseppe Matullo, BS, PhD f, Corrado Vassanelli, MD a, William Wijns, MD, PhD b
a Catheterization Laboratory of the Università del Piemonte Orientale, Ospedale Maggiore della Carità, Novara, Italy 
b Cardiovascular Center 
c Division of Radiation Oncology, OLV Hospital, Aalst, Belgium 
d Cardiovascular Research Foundation, New York, New YorkUSA 
e InterCorNet and the Division of Cardiology, University of Zurich, Zurich, Switzerland 
f Department of Genetics, Biology and Biochemistry, Università di Torino, Torino, Italy 

*Address for reprints: Valeria Ferrero, MD, Catheterization Laboratory, Università del Piemonte Orientale, Ospedale Maggiore della Carità, Corso Mazzini 18, 28100 Novara, Italy

Riassunto

This study tested the combination of vascular brachytherapy (VBT) and self-expanding Wallstent implantation in coronary lesions of patients at high risk for restenosis as assessed angiographically by quantitative coronary analysis and by 3-dimensional intravascular ultrasound analysis. Twenty-nine “de novo” lesions were managed with a self-expanding stent alone (n = 19) or with a self-expanding stent after β-VBT (n = 10) in 27 patients who had been identified by high levels of plasma angiotensin-converting enzyme as being prone to myointimal growth after stent implantation. At 6 months, the increase in stent strut diameter was similar in the 2 groups by quantitative coronary analysis and 3-dimensional intravascular ultrasound (Δ mean stent strut diameter −0.33 ± 0.3 vs −0.40 ± 0.3 mm, p = 0.5; Δ stent area −11.8 ± 6.1 vs −12.0 ± 6.1 mm2, p = 0.9; Δ stent volume −96.9 ± 112 vs −83.5 ± 73 mm3, p = 0.7; for groups treated with VBT and self-expanding stents and only self-expanding stents, respectively). In-stent neointimal proliferation was decreased in the group treated with VBT and self-expanding stents (minimal luminal diameter 2.5 ± 0.8 vs 1.88 ± 0.8 mm, p = 0.04) by quantitative coronary analysis (minimal luminal area 6.7 ± 2.5 vs 4.1 ± 1.9 mm2, p = 0.01), by intravascular ultrasound, and proliferation volume (84.6 ± 66.4 vs 159.2 ± 103.5 mm3, p = 0.05) by 3-dimensional intravascular ultrasound. Positive vessel and luminal remodelings were observed in 50% of the group treated with VBT and self-expanding stents and in 11% of the group treated only with self-expanding stents (p = 0.02). The combined use of VBT and self-expanding stents is a novel approach that enlarges vascular lumen by preventing vessel constriction and neointimal proliferation. The feasibility and good results of this experimental approach suggest that the simultaneous use of these 2 technologies may be an interesting alternative for difficult vascular districts with high restenosis rates, such as peripheral circulation in the lower limbs.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2004  Excerpta Medica Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 94 - N° 10

P. 1237-1242 - novembre 2004 Ritorno al numero
Articolo precedente Articolo precedente
  • Comparison of stress-induced myocardial ischemia in patients with and without coronary arterial collaterals
  • Farooq A. Chaudhry, Sripal Bangalore, Siu-Sun Yao, Kishin Ramani, Doyle Walton, Alexander Lee, Suhail Dohad
| Articolo seguente Articolo seguente
  • A Consumer Use Study of Over-the-Counter Lovastatin (CUSTOM)
  • Jeffrey M. Melin, William E. Struble, Robert W. Tipping, James M. Reynolds, Theodore C. Vassil, Stephanie J. Levy, Theresa M. Petrohoy, Paulette Midgette, Edwin L. Hemwall, Jeffrey G. Levine, John D. Irvin

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.