Abbonarsi

Randomized, controlled trial of standard-definition white-light, high-definition white-light, and narrow-band imaging colonoscopy for the detection of colon polyps and prediction of polyp histology - 27/08/11

Doi : 10.1016/j.gie.2011.04.050 
Amit Rastogi, MD a, b, , Dayna S. Early, MD c, Neil Gupta, MD b, Ajay Bansal, MD a, b, Vikas Singh, MD a, Michael Ansstas, MD c, Sreenivasa S. Jonnalagadda, MD c, Christine E. Hovis c, Srinivas Gaddam, MD a, Sachin B. Wani, MD b, Steven A. Edmundowicz, MD c, Prateek Sharma, MD a, b
a Veterans Affairs Medical Center, Kansas City, Missouri, USA 
b University of Kansas School of Medicine, Kansas City, Kansas, USA 
c Washington University, St. Louis, Missouri, USA 

Reprint requests: Amit Rastogi, MD, FASGE, University of Kansas School of Medicine, Kansas City Veterans Affairs Medical Center, 4801 East Linwood Blvd., Kansas City, MO 64128-2295

Riassunto

Background

Missing adenomas and the inability to accurately differentiate between polyp histology remain the main limitations of standard-definition white-light (SD-WL) colonoscopy.

Objective

To compare the adenoma detection rates of SD-WL with those of high-definition white-light (HD-WL) and narrow-band imaging (NBI) as well as the accuracy of predicting polyp histology.

Design

Multicenter, prospective, randomized, controlled trial.

Setting

Two academic medical centers in the United States.

Patients

Subjects undergoing screening or surveillance colonoscopy.

Intervention

Subjects were randomized to undergo colonoscopy with one of the following: SD-WL, HD-WL, or NBI.

Main Outcome Measurements

The proportion of subjects detected with adenomas, adenomas detected per subject, and the accuracy of predicting polyp histology real time.

Results

A total of 630 subjects were included. The proportion of subjects with adenomas was 38.6% with SD-WL compared with 45.7% with HD-WL and 46.2% with NBI (P = .17 and P = .14, respectively). Adenomas detected per subject were 0.69 with SD-WL compared with 1.12 with HD-WL and 1.13 with NBI (P = .016 and P = .014, respectively). HD-WL and NBI detected more subjects with flat and right-sided adenomas compared with SD-WL (all P values <.005). NBI had a superior sensitivity (90%) and accuracy (82%) to predict adenomas compared with SD-WL and HD-WL (all P values <.005).

Limitations

Academic medical centers with experienced endoscopists.

Conclusions

There was no difference in the proportion of subjects with adenomas detected with SD-WL, HD-WL, and NBI. However, HD-WL and NBI detected significantly more adenomas per subject (>60%) compared with SD-WL. NBI had the highest accuracy in predicting adenomas in real time during colonoscopy. (Clinical Trial registration number: NCT 00614770.)

Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : HD-WL, NBI, PIVI, SD-WL


Mappa


 Dr Rastogi was supported by a research grant from Olympus America Inc.
 DISCLOSURE: The following authors disclosed financial relationships relevant to this publication: Dr Rastogi: research grant from Olympus America Inc; Dr Edmundowicz: consultant to, honorarium from, and member of the advisory board of Olympus America Inc; Dr Sharma: grant support from Olympus America Inc. The other authors disclosed no financial relationships relevant to this publication. Dr Rastogi is the recipient of the Michael V. Sivak Jr. MD Endoscopic Research Award from the American Society for Gastrointestinal Endoscopy.
 See CME section; p. 634.
 If you would like to chat with an author of this article, you may contact Dr. Rastogi at amitr68@hotmail.com.


© 2011  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 74 - N° 3

P. 593-602 - settembre 2011 Ritorno al numero
Articolo precedente Articolo precedente
  • Will colon capsule endoscopy replace screening colonoscopy?
  • Jason A. Dominitz, Cynthia W. Ko
| Articolo seguente Articolo seguente
  • Narrow-band imaging versus I-Scan for the real-time histological prediction of diminutive colonic polyps: a prospective comparative study by using the simple unified endoscopic classification
  • Chang Kyun Lee, Suck-Ho Lee, Young Hwangbo

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.