Abbonarsi

Features of malignant biliary obstruction affecting the patency of metallic stents: A multicenter study - 01/09/11

Doi : 10.1067/mge.2002.121603 
Hyun Soo Kim, MD, Dong Ki Lee, MD, Ho Gak Kim, MD, Jong Jae Park, MD, Sang Heum Park, MD, Jin Hong Kim, MD, Byung Moo Yoo, MD, Im Hwan Roe, MD, Young Soo Moon, MD, Seung Jae Myung, MD
Wonju, Taegu, Inchon, Chunan, Suwon, and Seoul, Korea 
From the Departments of Internal Medicine, Yonsei University Wonju College of Medicine, Wonju, Taeku-Hyosung Catholic University, Taegu, Gacheon Medical College, Inchon, Soonchunhyang University, Chunan, Ajou University, Suwon, Dankook University, Chunan, Eulgi Medical College, Seoul, Korea 

Abstract

Background: Although placement of a metallic stent is an established therapeutic option for the palliation of patients with malignant biliary obstruction, it remains unclear which stricture-related or stent-related factors influence stent patency. Methods: Metallic stents were inserted endoscopically in 68 patients (38 men, 30 women; mean age 70.2 ± 8.5 years) with malignant biliary obstruction. Patency rates were prospectively analyzed according to malignant stricture characteristics, including length, morphologic type, and degree of narrowing. Furthermore, patient age, initial serum bilirubin level, length of stent, time to adequate expansion, and the location of the distal end of the stent were evaluated as possible factors affecting the stent patency. Stent patency was assessed by using the survival analysis of the Kaplan-Meier estimation and Cox regression analysis. Results: Median overall stent patency was 231 days (range 27-379 days) and the overall rate of stent occlusion 41.2% (28/68). The causes of occlusion were tumor ingrowth in 23 patients (33.8%), distal overgrowth in 3 (4.4%), proximal overgrowth in 1 (1.5%), and encrustation with sludge in 1 patient (1.5%). No significant differences in patency rates according to patient age, initial serum bilirubin level, primary tumor type, length and morphologic type of stricture, and length and location of the distal end of the stent were found. Cox regression analysis demonstrated that the degree of narrowing assessed by cannula or guidewire passage and the time to adequate expansion of the stent were independent factors associated with stent patency. Conclusion: Early expansion of the stent and easy passage of larger-caliber instruments through the stricture were favorable factors for long-term patency of the Wallstent. (Gastrointest Endosc 2002;55:359-65.)

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 Reprint requests: D. K. Lee, MD, Division of Gastroenterology Department of Internal Medicine, Yonsei University Wonju College of Medicine, 162, Ilsan-Dong, Wonju, 220-701, Republic of Korea.


© 2002  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 55 - N° 3

P. 359-365 - marzo 2002 Ritorno al numero
Articolo precedente Articolo precedente
  • “Tannenbaum” Teflon stents versus traditional polyethylene stents for treatment of malignant biliary stricture
  • Marc F. Catalano, Joseph E. Geenen, Glen A. Lehman, Jerome H. Siegel, Leslie Jacob, Matthew J. McKinley, Isaac Raijman, Peter Meier, Ira Jacobson, Richard Kozarek, Firas H. Al-Kawas, Simon K. Lo, Kulwinder S. Dua, John Baille, Gregory G. Ginsberg, William Parsons, Scott M. Meyerson, Seth Cohen, Douglas B. Nelson, James D. McHattie, David L. Carr-Locke
| Articolo seguente Articolo seguente
  • Moving?

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.