Abbonarsi

The variable stiffness colonoscope: Assessment of efficacy by magnetic endoscope imaging - 01/09/11

Doi : 10.1016/S0016-5107(02)70177-6 
Syed G. Shah, MRCP, Jim C. Brooker, MRCP, Christopher B. Williams, FRCP, FRCS, Catherine Thapar, RGN, Noriko Suzuki, MD, Brian P. Saunders, MD
Current affiliations: Wolfson Unit for Endoscopy, St. Mark's Hospital, London, United Kingdom 

Abstract

Background: Variable-stiffness colonoscopes combine the flexibility of pediatric instruments for negotiation of the sigmoid colon with the ability to stiffen the insertion tube to prevent or control looping after straightening. Previous studies have found wide variation in the efficacy of the stiffening mechanism. Thus, two studies were conducted to assess the potential benefit of the stiffening device and its optimal use. Methods: In study 1, the effect of routinely stiffening the straightened variable-stiffness colonoscopes in the mid-descending colon was determined in 82 patients. Two insertions were performed (mid-descending colon to cecum) in each patient with and without application of the stiffening device (randomized). The time to negotiate the proximal colon (mid-descending to cecum), time to pass the variable-stiffness colonoscopes across the splenic flexure into the transverse colon, time to pass the right colon, and ancillary maneuvers used were recorded for each insertion. In study 2, consecutive patients, excluding any with previous colonic resection, were examined by using standard adult variable-stiffness colonoscopes. Real-time views of the procedure with magnetic endoscope imaging were recorded for all examinations, but procedures were randomized to be done either with (n = 88), or without (n = 87) the endoscopist viewing the magnetic endoscope imaging display. Whenever stiffening was applied, the anatomic location of the colonoscope tip and stiffness efficacy were recorded. Results: In study 1, time taken to negotiate the proximal colon (p = 0.0041) and time to negotiate the splenic flexure (p = 0.006) were significantly shorter and ancillary maneuvers performed were fewer (p = 0.0014) with the stiffening device activated. In study 2, stiffening was used with similar frequency in patients examined with and without the magnetic endoscope imaging view, most commonly for passing the splenic flexure (71%), but also in the transverse colon (12%), right colon (9%), and sigmoid/descending colon (8%). Stiffening was significantly more effective when used in combination with magnetic endoscope imaging (69% with imager vs. 45% without imager; p = 0.0102). Conclusions: Overall, the variable-stiffness device used was effective in controlling looping 57% of the time. Activating maximum stiffness appears to be effective once the sigmoid colon has been negotiated and the colonoscope straightened with the tip in the proximal colon, reducing the number of ancillary maneuvers and shortening the insertion time through the proximal colon. Routine magnetic endoscope imaging further enhances the efficacy of the variable-stiffness colonoscopes by helping to identify the optimal time for stiffening. (Gastrointest Endosc 2002;56:195-201.)

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 Funding by Trusthouse Charitable Foundation.
 Reprint requests: Dr. Brian P. Saunders, Wolfson Unit for Endoscopy, St. Mark's Hospital, Watford Road, Harrow, Middlesex, London, United Kingdom, HAL 3UJ.


© 2002  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 56 - N° 2

P. 195-201 - agosto 2002 Ritorno al numero
Articolo precedente Articolo precedente
  • Minimizing postcolonoscopy abdominal pain by using CO2 insufflation: A prospective, randomized, double blind, controlled trial evaluating a new commercially available CO2 delivery system
  • Katica Sumanac, Ian Zealley, Bruce M. Fox, John Rawlinson, Bruno Salena, John K. Marshall, Giles W. Stevenson, Richard H. Hunt
| Articolo seguente Articolo seguente
  • Nifedipine for prevention of post-ERCP pancreatitis: A prospective, double-blind randomized study
  • Frédéric Prat, Juan Amaris, Béatrice Ducot, Muriel Bocquentin, Jacques Fritsch, André Daniel Choury, Gilles Pelletier, Catherine Buffet

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.