Abbonarsi

Patient-maintained sedation for ERCP with a target-controlled infusion of propofol: A pilot study - 03/09/11

Doi : 10.1067/mge.2001.116358 
Mike J. Gillham, FANZCA, Rachael C. Hutchinson, FRCA, Ross Carter, FRCS, Gavin N.C. Kenny, MD, FRCA
University Department of Anaesthesia and Department of Upper GI and Pancreatico-Biliary Surgery, Royal Infirmary, Glasgow, United Kingdom 

Abstract

Background: ERCP requires patient cooperation and often prolonged sedation. In different areas of anesthetic practice, patient-controlled sedation with a target-controlled infusion (TCI) of propofol provides effective sedation. The aim of this study was to assess the safety and efficacy of the same system in patients undergoing ERCP. Methods: Twenty patients used the TCI system. Patients received oxygen at 2 L/min via nasal cannulae. By using pharmacokinetic TCI software modeling, an initial propofol target blood concentration (Ct) of 1.0 μg/mL was supplemented on patient demand with a handset that, when pressed twice within 1 second, increased the Ct of propofol by 0.2 μg/mL. The maximum permissible target concentration was set at 3.0 μg/mL to prevent oversedation. Results: Sixteen patients used the system successfully throughout the procedure. The Ct propofol ranged from 1.2 to 2.6 μg/mL, and the number of successful handset activations (after commencement of the ERCP) ranged from 0 to 3. In 3 patients, the ceiling Ct propofol was attained without adequate sedation and the system was manually overridden. The system failed in 1 case because of patient confusion. There were no episodes of hemodynamic instability, airway obstruction, or significant oxygen desaturation. Endoscopist and patient satisfaction were high. Four patients were oversedated according to our criteria at the end of the procedure, but all were awake within 5 minutes of arrival in the recovery area. Conclusions: Patient-maintained sedation with TCI propofol was safe and fully effective in 16 patients. Ease of endoscopy was rated high by the endoscopists, and all patients were well satisfied with their sedation. Adjustments to the software programming are being evaluated to increase the safety profile to avoid oversedation. (Gastrointest Endosc 2001;54:14-7.)

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 Reprint requests: Professor G. N. C. Kenny, University Department of Anaesthesia, Royal Infirmary, 10 Alexandra Parade, Glasgow G31 2ER, UK.
 Gastrointest Endosc 2001;54:14-7


© 2001  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 54 - N° 1

P. 14-17 - luglio 2001 Ritorno al numero
Articolo precedente Articolo precedente
  • Patient-controlled sedation with propofol for colonoscopy
  • Ju-Mei Ng, Chee-Fai Kong, Denis Nyam
| Articolo seguente Articolo seguente
  • Feasibility and potential benefit of maintenance endoscopic variceal ligation in patients with unresectable hepatocellular carcinoma and acute esophageal variceal hemorrhage: a controlled trial
  • Wen-Chi Chen, Ming-Chih Hou, Han-Chieh Lin, Fa-Yauh Lee, Yu-Yun Yeh, Full-Young Chang, Shou-Dong Lee

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.