Abbonarsi

Prospective randomized trial comparing Tannenbaum Teflon and standard polyethylene stents in distal malignant biliary stenosis - 05/09/11

Doi : 10.1016/S0016-5107(00)70381-6 
Vittorio Terruzzi, MD, Umberto Comin, MD, Federico De Grazia, MD, Gian Luigi Toti, MD, Alessandro Zambelli, MD, Sandro Beretta, MD, Giorgio Minoli, MD
Como, Magenta, Crema, Milan, Italy 
From Unità di Gastroenterologia, Divisione di Medicina 2, and Unità di Biostatistica, Ospedale Valduce, Como; Servizio di Endoscopia, Ospedale Civile di Magenta, Milano; Servizio di Endoscopia, Ospedale Maggiore, Crema; and Ospedale Civile di Sesto S. Giovanni, Milano, Italy 

Abstract

Background:  Our aim was to compare the clinical efficacy of the Tannenbaum (TB) biliary prostheses, a recently designed Teflon stent without side holes, with the Cotton-Huibregtse (CH) polyethylene stent. Methods:  Fifty-seven patients (26 men, mean age 75.5 years) with unresectable malignant tumors and distal biliary stenosis were included (38 pancreatic head cancer, 17 cholangiocarcinoma, 2 ampullary cancer). Patients were prospectively randomized to have a 10F, 7 cm long TB (29 patients) or CH (28 patients) stent inserted endoscopically. Four patients (2 TB and 2 CH) were excluded: 3 because of the failure of stent insertion and 1 because of a protocol violation. The patients were evaluated clinically and, if necessary, with biochemical tests every month until death or until they needed surgery for symptoms of gastric outlet obstruction. When occlusion or dislocation occurred, the stent was replaced with one of the same type. Cumulative stent patency and patient survival were estimated with the Kaplan-Meier life-table analysis and compared by log-rank chi-square test. Results:  The two groups were comparable in mean age, gender, and diagnosis. The patients were followed for a mean of 145.5 days (range 24 to 613); by the end of the study 47 patients (81%) had died or developed symptoms of gastric outlet obstruction. Median survival was 88 days (range 24 to 613) in the TB group and 75.6 days (23 to 486) in the CH group. Stent exchange (occlusion 16, dislocation 3) was necessary for 5 patients in the TB group and 7 in the CH group. No statistical difference was found on comparing the mean duration of function of the first, second, and third stents (analysis of variance, p = 0.80). The median duration of stent function was 96 days (range 11 to 613) in the TB group and 75.5 days (range 23 to 323) in the CH group. No significant difference was found in either survival time (p = 0.48) or stent patency (p = 0.12). Conclusion:  This study found no significant advantage of the Tannenbaum prostheses over the standard polyethylene stent in the palliation for patients with distal malignant biliary stenosis with regard to survival or length of stent patency. (Gastrointest Endosc 2000;51:23-7.)

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 Supported in part by Cook Italia.
 Reprint requests: Vittorio Terruzzi, MD, Divisione di Medicina 2, Ospedale Valduce, via Dante 11, I - 22100 Como, Italy.
 0016-5107/2000/$12.00 + 0   37/1/102787


© 2000  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 51 - N° 1

P. 23-27 - gennaio 2000 Ritorno al numero
Articolo precedente Articolo precedente
  • Coming Next Issue…
| Articolo seguente Articolo seguente
  • In Upcoming Issues…

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.