Abbonarsi

Tissue proliferation within and surrounding Palmaz-Schatz stents is dependent on the aggressiveness of stent implantation technique - 08/09/11

Doi : 10.1016/S0002-9149(99)00053-3 
Rainer Hoffmann, MD a, Gary S. Mintz, MD a, Roxana Mehran, MD a, Kenneth M. Kent, MD, PhD a, Augusto D. Pichard, MD a, Lowell F. Satler, MD a, Martin B. Leon, MD a,
a Intravascular Ultrasound Imaging and Cardiac Catheterization Laboratories, Washington Hospital Center, Washington, DC, USA 

*Address for reprints: Martin B. Leon, MD, Washington Cardiology Center, 110 Irving Street NW, Suite 4B1, Washington, DC 20010

Abstract

In-stent restenosis is entirely due to intimal hyperplasia. Histologic studies have indicated that intimal hyperplasia is related to the arterial injury induced during stent implantation. We used intravascular ultrasound (IVUS) imaging to study whether tissue proliferation inside and surrounding stents is related to the aggressiveness of the implantation technique. After intervention and follow-up (mean 5.6 ± 3.7 months), serial IVUS imaging was performed in 102 native artery stented stenoses in 91 patients. Measurements at 5 predetermined segments within each stented lesion included external elastic membrane, stent, and lumen cross-sectional areas (CSAs). Calculations included mean plaque CSA growth outside of the stent (external elastic membrane-stent) and mean neointimal hyperplasia CSA and thickness within the stent (stent-lumen). Stenoses were categorized depending on the aggressiveness of stent placement (group 1, adjunct percutaneous transluminal coronary angioplasty pressure <16 atm and/or balloon/artery ratio <1.1; group 2, adjunct percutaneous transluminal coronary angioplasty pressure ≥16 atm and balloon/artery ratio ≥1.1). An aggressiveness score was calculated as balloon/artery ratio · inflation pressure. Mean intimal hyperplasia CSA (2.9 ± 1.5 vs 2.2 ± 1.6 mm2, p = 0.028), mean intimal hyperplasia thickness (0.34 ± 0.19 vs 0.25 ± 0.19 mm, p = 0.012), and mean peristent tissue growth CSA (2.5 ± 1.0 vs 1.1 ± 1.4 mm2, p = 0.003) were significantly greater in group 2 stenoses. In addition, intimal hyperplasia CSA and thickness correlated significantly with balloon/artery ratio · inflation pressures: r = 0.305, p = 0.002 and r = 0.329, p = 0.0007, respectively, as did peristent tissue proliferation CSA (r = 0.466, p = 0.001). Tissue proliferation inside and surrounding stents may be related to aggressiveness of the stent implantation technique.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 This study was supported in part by an educational grant from the Cardiology Research Foundation, Washington, DC.


© 1999  Excerpta Medica Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 83 - N° 8

P. 1170-1174 - aprile 1999 Ritorno al numero
Articolo precedente Articolo precedente
  • Determinants of stent restenosis in chronic coronary occlusions assessed by intracoronary ultrasound
  • Gerald S Werner, Oliver Gastmann, Markus Ferrari, Karl H Scholz, Seda Schünemann, Hans R Figulla
| Articolo seguente Articolo seguente
  • A proposed strategy for utilization of creatine kinase-MB and troponin I in the evaluation of acute chest pain
  • Carı́si A Polanczyk, Paula A Johnson, E.Francis Cook, Thomas H Lee

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.