Abbonarsi

A randomized, investigator-blinded, controlled pilot study to evaluate the safety and efficacy of a poly-N-acetyl glucosamine–derived membrane material in patients with venous leg ulcers - 13/05/12

Doi : 10.1016/j.jaad.2011.01.031 
Teresa J. Kelechi, PhD, RN a, , Martina Mueller, PhD a, Cheryl S. Hankin, PhD b, Amy Bronstone, PhD b, John Samies, MD c, Phyllis A. Bonham, PhD, RN a
a Medical University of South Carolina, Charleston, South Carolina 
b BioMedEcon, Moss Beach, California 
c Regional Medical Center of Orangeburg, Orangeburg, South Carolina 

Reprint requests: Teresa J. Kelechi, PhD, RN, College of Nursing, Medical University of South Carolina, 99 Jonathan Lucas St, MSC 160, Charleston, SC 29425-1600.

Abstract

Background

Standard care for venous leg ulcers (VLUs) has remained unchanged over several decades despite high rates of initial treatment failure and ulcer recurrence.

Objective

We sought to evaluate the efficacy, safety, and tolerability of an advanced, poly-N-acetyl glucosamine (pGlcNAc), nanofiber-derived, wound-healing technology among patients with VLUs (Talymed, Marine Polymer Technologies Inc, Danvers, MA).

Methods

In this randomized, investigator-blinded, parallel-group, controlled study, eligible patients were randomized to treatment with standard care plus pGlcNAc (applied only once, every other week, or every 3 weeks) or to standard care alone. The primary end point was the proportion of patients with complete wound healing at week 20 in the intent-to-treat population (all randomized subjects), with last observation carried forward.

Results

Among 82 randomized patients, 71 completed the study with 7 lost to follow-up and 4 discontinued because of systemic infection. There were no significant group differences with regard to baseline demographic, illness, and VLU characteristics. At 20 weeks, the proportion of patients with completely healed VLUs was 45.0% (n = 9 of 20), 86.4% (n = 19 of 22), and 65.0% (n = 13 of 20) for groups receiving standard care plus pGlcNAc only once, every other week, and every 3 weeks, respectively, versus 45.0% (n = 9 of 20) for those receiving standard care alone (P < .01 for pGlcNAc every other week vs standard care). The novel pGlcNAc advanced wound-healing technology was well tolerated and safe.

Limitations

Limitations were small sample size and patients unblinded to treatment allocation.

Conclusion

These pilot study results suggest that the pGlcNAc advanced wound-healing technology is well tolerated and effective.

Il testo completo di questo articolo è disponibile in PDF.

Key words : membrane, poly-N-acetyl glucosamine, therapy, venous leg ulcer, wound healing

Abbreviations used : FDA, pGlcNAc, VLU


Mappa


 Supported by Marine Polymer Technologies Inc.
 Drs Kelechi, Mueller, and Bonham have received grant support from, and Drs Hankin, Bronstone, and Samies are consultants to, Marine Polymer Technologies Inc.


© 2011  American Academy of Dermatology, Inc.. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 66 - N° 6

P. e209-e215 - giugno 2012 Ritorno al numero
Articolo precedente Articolo precedente
  • Neuropeptide Y expression in cutaneous melanoma
  • Yolanda Gilaberte, M. Jose Roca, M. Dolores Garcia-Prats, Carmen Coscojuela, M. Dolores Arbues, Jesús J. Vera-Alvarez
| Articolo seguente Articolo seguente
  • Chronic mucocutaneous herpes simplex virus and varicella zoster virus infections
  • Odile Wauters, Eglantine Lebas, Arjen F. Nikkels

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.