Abbonarsi

Différences induites par la définition des périodes diurnes et nocturnes sur la pression artérielle et le dipping lors d’une mesure ambulatoire de la pression artérielle - 24/08/12

Doi : 10.1016/j.ancard.2012.04.016 
M.-E. Muller a, M. Bochud b, M. Pruijm a, K. Iglesias b, c, M. Burnier a, G. Wuerzner a, ⁎, c
a Service de néphrologie et d’hypertension, CHU Vaudois, rue du Bugnon 17, 1011 Lausanne, Suisse 
b Institut universitaire de médecine sociale et préventive, Lausanne, Suisse 
c Centre de recherche clinique, CHU Vaudois, Lausanne, Suisse 

Auteur correspondant.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 5
Iconografia 2
Video 0
Altro 0

Résumé

La mesure ambulatoire de la pression artérielle (MAPA) est devenue un outil indispensable dans le diagnostic et le contrôle de la pression artérielle (PA). Il n’existe cependant aucun consensus concernant la définition des périodes diurnes ou nocturnes lors des MAPA.

But de l’étude

Comparer les valeurs de PA diurnes et nocturnes et la baisse nocturne de la PA (dipping) définies par un actigraphe et par la position du corps aux valeurs calculées sur des périodes fixées arbitrairement.

Patients et méthodes

Enregistrement simultané de la MAPA, des périodes de sommeil et de la position du corps (débout/allongé) par un actigraphe (SenseWear Armband®) chez des patients référés pour une MAPA. Les résultats obtenus par l’actigraphe (sommeil et position) étaient comparés aux résultats obtenus par une période de jour (07h00–22h00) et de nuit (22h00–07h00) fixées arbitrairement.

Résultats

Les données de 103 patients, dont plus de la moitié étaient traités pour une hypertension, ont été analysées. Par rapport aux périodes fixées arbitrairement, les PA nocturnes étaient plus basses (PA systolique : 2,08±4,50mmHg ; PA diastolique : 1,84±2,99mmHg, p<0,05) et le dipping était plus marqué (PA systolique : 1,54±3,76 % ; PA diastolique : 2,27±3,48 %, p<0,05) lorsque la période nocturne était définie par l’actigraphe. Les valeurs en position debout étaient supérieures (PA systolique : 1,07±2,81mmHg ; PA diastolique : 1,34±2,50mmHg) aux valeurs diurnes de la période diurne fixée.

Conclusion

La PA diurne et nocturne ainsi que le dipping sont influencés par la méthode utilisée pour définir l’intervalle nocturne. Le choix d’une méthode par rapport à une autre dépendra de la valeur pronostique de chaque méthode sur des évènements cardiovasculaires.

Il testo completo di questo articolo è disponibile in PDF.

Abstract

Ambulatory blood pressure monitoring (ABPM) has become indispensable for the diagnosis and control of hypertension. However, no consensus exists on how daytime and nighttime periods should be defined.

Objective

To compare daytime and nighttime blood pressure (BP) defined by an actigraph and by body position with BP resulting from arbitrary daytime and nighttime periods.

Patients and method

ABPM, sleeping periods and body position were recorded simultaneously using an actigraph (SenseWear Armband®) in patients referred for ABPM. BP results obtained with the actigraph (sleep and position) were compared to the results obtained with fixed daytime (7a.m.–10p.m.) and nighttime (10p.m.–7a.m.) periods.

Results

Data from 103 participants were available. More than half of them were taking antihypertensive drugs. Nocturnal BP was lower (systolic BP: 2.08±4.50mmHg; diastolic BP: 1.84±2.99mmHg, P<0.05) and dipping was more marked (systolic BP: 1.54±3.76%; diastolic BP: 2.27±3.48%, P<0.05) when nighttime was defined with the actigraph. Standing BP was higher (systolic BP 1.07±2.81mmHg; diastolic BP: 1.34±2.50mmHg) than daytime BP defined by a fixed period.

Conclusion

Diurnal BP, nocturnal BP and dipping are influenced by the definition of daytime and nighttime periods. Studies evaluating the prognostic value of each method are needed to clarify which definition should be used.

Il testo completo di questo articolo è disponibile in PDF.

Mots clés : Hypertension, Mesure ambulatoire de la pression artérielle, Dipping, Actigraphe

Keywords : Hypertension, Ambulatory blood pressure monitoring, Actigraph, Dipping


Mappa


© 2012  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 61 - N° 3

P. 193-197 - giugno 2012 Ritorno al numero
Articolo precedente Articolo precedente
  • Une nouvelle méthode spontanée pour l’évaluation du baroréflexe sympathique chez l’Homme
  • C. Gallet, M. Gujic, D. Laude, P. van de Borne, C. Julien
| Articolo seguente Articolo seguente
  • Influence de la variabilité de la pression artérielle en consultation sur le diagnostic du contrôle tensionnel chez des hypertendus traités
  • F. Villeneuve, D. Rosenbaum, C. Gury, X. Girerd

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.