Abbonarsi

Successful Localization of Recurrent Thyroid Cancer in Reoperative Neck Surgery Using Ultrasound-Guided Methylene Blue Dye Injection - 14/09/12

Doi : 10.1016/j.jamcollsurg.2012.06.006 
Avital Harari, MD a, , Rebecca S. Sippel, MD, FACS b, Ruth Goldstein, MD c, Seerat Aziz, MD c, Wen Shen, MD, FACS d, Jessica Gosnell, MD, FACS d, Quan-Yang Duh, MD, FACS d, Orlo H. Clark, MD, FACS d
a University of California, Los Angeles, Section of Endocrine Surgery, Los Angeles, CA 
b University of Wisconsin, Section of Endocrine Surgery, Madison, WI 
c Department of Radiology, University of California, San Francisco, San Francisco, CA 
d Division of Endocrine Surgery, University of California, San Francisco, San Francisco, CA 

Correspondence address: Avital Harari, MD, Department of Surgery, University of California, Los Angeles, 10833 LeConte Ave, Suite 72-232 CHS, Los Angeles, CA 90095

Riassunto

Background

Reoperation in the neck can be challenging and is associated with increased complication rates and operative times. Here we analyze our methylene blue dye injection method to localize reoperative neck pathology in patients with thyroid cancer and lymph node metastases.

Study Design

We retrospectively reviewed the records of all patients at a single university tertiary care center who had reoperative neck surgery for recurrent thyroid cancer between 2004 and 2009, and who also underwent intraoperative methylene blue dye injection. Outcomes measured were efficacy and safety of the injection technique as well as complication rates.

Results

Fifty-three operations were performed in 44 patients (average age, 51.2 years [range 16 to 83 years]). Ninety-one percent (48 of 53) of the operations resulted in successful resection of recurrent disease. Of these, 96% (46 of 48) were guided successfully by blue dye injection. Thyroglobulin became undetectable in 42% (11 of 26) of patients. Neck pathology included the following thyroid cancers: papillary (48 of 53), follicular (2 of 53), medullary (2 of 53), and tall cell variant (1 of 53). Among these patients, there were a total of 26 central and 38 lateral neck dissections. The average number of previous neck dissections was 2 (range 1 to 5). The mean intraoperative ultrasound/injection time was 21.3 min (n = 13). Median operative time was 90 minutes (range 40 to 300 minutes). Complications included 2 permanent vocal cord paralyses, 1 instance of permanent hypocalcemia, and 3 instances of temporary hypocalcemia. There were no complications related to the dye injection.

Conclusions

Intraoperative, ultrasound-guided, methylene blue dye injection is a safe and effective technique. It facilitates tumor localization and removal especially in patients requiring reoperative neck surgery.

Il testo completo di questo articolo è disponibile in PDF.

Abbreviations and Acronyms : FNA, RAI, RLN


Mappa


 Disclosure Information: Nothing to disclose.


© 2012  American College of Surgeons. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 215 - N° 4

P. 555-561 - ottobre 2012 Ritorno al numero
Articolo precedente Articolo precedente
  • Intraoperative Pathologic Examination in the Era of Molecular Testing for Differentiated Thyroid Cancer
  • Kelly L. McCoy, Sally E. Carty, Michaele J. Armstrong, Raja R. Seethala, N. Paul Ohori, Adam S. Kabaker, Michael T. Stang, Steven P. Hodak, Yuri E. Nikiforov, Linwah Yip
| Articolo seguente Articolo seguente
  • Preoperative Needle Biopsy Improves the Quality of Breast Cancer Surgery
  • Ted A. James, John L. Mace, Beth A. Virnig, Berta M. Geller

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.