Abbonarsi

Coronary angiographic scoring systems: An evaluation of their equivalence and validity - 15/10/12

Doi : 10.1016/j.ahj.2012.07.007 
Ian J. Neeland, MD a, f, Riyaz S. Patel, MD b, c, f, Parham Eshtehardi, MD c, Saurabh Dhawan, MD c, Michael C. McDaniel, MD c, S. Tanveer Rab, MD c, Viola Vaccarino, MD, PhD c, d, A. Maziar Zafari, MD, PhD c, e, Habib Samady, MD c, Arshed A. Quyyumi, MD c,
a Department of Internal Medicine, Division of Cardiology, University of Texas Southwestern Medical Center, Dallas, TX 
b Cardiff University, Cardiff, Wales, United Kingdom 
c Division of Cardiology, Emory University School of Medicine, Atlanta, GA 
d Emory University Rollins School of Public Health, Atlanta, GA 
e Atlanta Veterans Affairs Medical Center, Decatur, GA 

Reprint requests: Arshed A. Quyyumi, MD, Emory University School of Medicine, 1462 Clifton Road, Suite 506, Atlanta, GA 30322.

Riassunto

Background

Multiple scoring systems have been devised to quantify angiographic coronary artery disease (CAD) burden, but it is unclear how these scores relate to each other and which scores are most accurate. The aim of this study was to compare coronary angiographic scoring systems (1) with each other and (2) with intravascular ultrasound (IVUS)–derived plaque burden in a population undergoing angiographic evaluation for CAD.

Methods

Coronary angiographic data from 3600 patients were scored using 10 commonly used angiographic scoring systems and interscore correlations were calculated. In a subset of 50 patients, plaque burden and plaque area in the left anterior descending coronary artery were quantified using IVUS and correlated with angiographic scores.

Results

All angiographic scores correlated with each other (range for Spearman coefficient [ρ] 0.79-0.98, P < .0001); the 2 most widely used scores, Gensini and CASS-70, had a ρ = 0.90 (P < .0001). All scores correlated significantly with average plaque burden and plaque area by IVUS (range ρ 0.56-0.78, P < .0001 and 0.43-0.62, P < .01, respectively). The CASS-50 score had the strongest correlation (ρ 0.78 and 0.62, P < .0001) and the Duke Jeopardy score the weakest correlation (ρ 0.56 and 0.43, P < .01) with plaque burden and area, respectively.

Conclusions

Angiographic scoring systems are strongly correlated with each other and with atherosclerotic plaque burden. Scoring systems therefore appear to be a valid estimate of CAD plaque burden.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2012  Mosby, Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 164 - N° 4

P. 547 - ottobre 2012 Ritorno al numero
Articolo precedente Articolo precedente
  • Impact of system delay on infarct size, myocardial salvage index, and left ventricular function in patients with ST-segment elevation myocardial infarction
  • Jacob Lønborg, Mikkel Malby Schoos, Henning Kelbæk, Lene Holmvang, Jacob Steinmetz, Niels Vejlstrup, Erik Jørgensen, Steffen Helqvist, Kari Saunamäki, Hans Erik Bøtker, Won Yong Kim, Christian Juhl Terkelsen, Peter Clemmensen, Thomas Engstrøm
| Articolo seguente Articolo seguente
  • Red versus white thrombi in patients with ST-elevation myocardial infarction undergoing primary percutaneous coronary intervention: clinical and angiographic outcomes
  • Alexandre S. Quadros, Eduardo Cambruzzi, Juliana Sebben, Renato B. David, Anibal Abelin, Dulce Welter, Rogério Sarmento-Leite, Rajendra H. Mehta, Carlos A. Gottschall, Renato D. Lopes

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.