Abbonarsi

Improving cardiac function with new-generation plasma volume expanders - 08/12/12

Doi : 10.1016/j.ajem.2012.05.031 
Surapong Chatpun a, b, Parimala Nacharaju c, Pedro Cabrales, PhD a, ⁎
a Department of Bioengineering, University of California–San Diego, La Jolla, CA 92093, USA 
b Institute of Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Songkhla, 90110, Thailand 
c Department of Physiology and Biophysics, Albert Einstein College of Medicine, Bronx, NY 10461, USA 

⁎Corresponding author. Tel.: +1 858 534 8197.

Abstract

Background

Plasma expander (PE) based on polyethylene glycol (PEG) conjugated to albumin has shown positive results maintaining blood volume during hemodilution and restoring blood volume during resuscitation from hemorrhagic shock. Polyethylene glycol conjugation to human serum albumin (HSA), PEG-HSA, increases size, weight, and colloidal osmotic pressure, with minor effects on solution viscosity.

Methods

This study was designed to test the hypothesis that PEG-HSA (2 g/dL) produced by direct PEGylation chemistry improves cardiac function during 2 experimental models, (i) moderate hemodilution and (ii) resuscitation from hemorrhagic shock, compared with a conventional colloidal PE (Dextran 70 kd [Dx70], 6 g/dL). Cardiac function was studied using a miniaturized pressure volume conductance catheter implanted in the left ventricle and evaluated in terms of cardiac indices derived from the pressure volume measurements.

Results

Polyethylene glycol–HSA increased cardiac output, stroke volume, and stroke work and decreased systemic vascular resistance compared with Dx70 in both experimental models. The improvements induced by PEG-HSA in cardiac function were sustained over the observation time. Polyethylene glycol–HSA cardiac mechanoenergetics changes are the result of increased energy transferred per stroke and decreased resistance of the vasculature connecting the heart. In summary, PEG-HSA decreased left ventricle ejection impedance.

Conclusion

Ejection of blood diluted with PEG-HSA presented a reduced load to the heart, increased contractile function, and lowered the energy consumed per unit volume compared with Dx70. Our results emphasize the importance of heart function as a parameter to be included in the evaluation changes induced by new PEs.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2013  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 31 - N° 1

P. 54-63 - gennaio 2013 Ritorno al numero
Articolo precedente Articolo precedente
  • Brain computed tomographic scan findings in acute opium overdose patients
  • Farkhondeh Jamshidi, Babak Sadighi, Kamran Aghakhani, Hossein Sanaei-Zadeh, Mohammadali Emamhadi, Nasim Zamani
| Articolo seguente Articolo seguente
  • End-tidal carbon dioxide is associated with mortality and lactate in patients with suspected sepsis
  • Christopher L. Hunter, Salvatore Silvestri, Matthew Dean, Jay L. Falk, Linda Papa

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.