Trabecular microarchitecture in established osteoporosis: Relationship between vertebrae, distal radius and calcaneus by X-ray imaging texture analysis - 02/02/13

Doi : 10.1016/j.otsr.2012.08.004 
F. Mallard a, c, B. Bouvard a, P. Mercier b, P. Bizot c, P. Cronier b, c, D. Chappard a,
a LUNAM, Angers University, Bone remodeling and biomaterials study group (GEROM)–LHEA, IRIS-IBS Biology Institute of Health, Angers Universitary Hospital Center, 49933 Angers Cedex, France 
b LUNAM, Angers University, Anatomy Research Laboratory, Faculy of Medicine, 49000 Angers, France 
c Department of Orthopaedic Surgery,Angers Teaching Hospital Center, 49933 Angers Cedex, France 

Corresponding author. Tel.: +33 244 68 83 49; fax: +33 244 68 83 50.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Summary

Introduction

Osteoporosis is an alteration of bone mass and microarchitecture leading to an increased risk of fractures. A radiograph is a 2D projection of the 3D bone network exposing a texture, that can be assessed by texture analysis. We compared the trabecular microarchitecture of the spine, radius and calcaneus in a series of osteoporotic cadavers.

Materials and methods

Thirty-four cadavers (11 men, 23 women), mean age 85.2±2.1years, were radiographed from T4 to L5 to identify those with vertebral fractures (FV). Non-fractured vertebrae (NFV), radius and calcaneus were taken and analyzed by densitometry, radiography and texture analysis under run-length, skeletonization of the trabeculae, and fractal geometry.

Results

Six subjects (five women, one man) were selected, mean age 82.5±5.5years. Twelve calcanei and 10 radii were taken. Two radii were excluded. The texture of NFV was significantly correlated (P<0.01) with that of the radius for horizontal run-lengths. No relationship between the texture of NFV and calcaneus was found.

Discussion

In the horizontal direction (perpendicular to the stress lines), the microarchitecture of NFV and radius showed a disappearance of the transverse rods anchoring the plates. Due to its particular microarchitecture, the calcaneus is not representative of the vertebral status.

Conclusion

Bone densitometry provides no information about microarchitecture. Texture analysis of X-ray images of the radius would be a minimally invasive tool, providing an early detection of microarchitectural alterations.

Level of evidence

IV retrospective study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Bone microarchitecture, Texture analysis, Vertebral fracture, Calcaneus, Radius


Mappa


© 2012  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 99 - N° 1

P. 52-59 - febbraio 2013 Ritorno al numero
Articolo precedente Articolo precedente
  • CT scan does not improve the reproducibility of trochanteric fracture classification: A prospective observational study of 53 cases
  • E. Cavaignac, M. Lecoq, A. Ponsot, A. Moine, N. Bonnevialle, P. Mansat, N. Sans, P. Bonnevialle
| Articolo seguente Articolo seguente
  • Early diagnosis of thoracolumbar spine fractures in children. A prospective study
  • J. Leroux, P.-H. Vivier, M. Ould Slimane, E. Foulongne, S. Abu-Amara, J. Lechevallier, J. Griffet

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.