Background

Recent studies have shown that short duration ventricular fibrillation (SDVF) and long duration ventricular fibrillation (LDVF) are maintained by different mechanisms. The objective of this study is to evaluate how the defibrillation threshold (DFT) varies over the duration of fibrillation since the mechanism of VF maintenance changes as VF progresses.

Methods

Twelve canines were randomly divided into two groups (Group A and B, n=6 each). DFTs were measured three times in each group: SDVF (20s), LDVF (3min in Group A and 7min in Group B) and the first episode of refibrillation after successful defibrillation for LDVF. Two 64-electrode baskets used to globally map the endocardium were deployed into the left ventricle and right ventricle, respectively.

Results

LDVF-DFT in Group A was significantly higher than that of Group B (628±98V vs 313±81V, P<0.001). In Group B, the DFT of refibrillation was significantly increased compared with the LDVF-DFT (570±199V vs 313±81V, P=0.035) but did not differ from the DFT of refibrillation in Group A (570±199V vs 638±116V, P=0.39). Highly synchronised activation patterns on the left ventricular endocardium were observed between 3 and 7min of LDVF in Group B but not within 3min-LDVF in Group A or during refibrillation in each group.

Conclusions

DFT varied during different stages of VF. The highly synchronised activation patterns exhibiting after 3min VF might contribute to the decreased LDVF-DFT.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Ventricular fibrillation, Defibrillation, Electrophysiology, Resuscitation


Mappa


© 2012  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 22 - N° 2

P. 133-140 - febbraio 2013 Ritorno al numero
Articolo precedente Articolo precedente
  • Early and Delayed Tranilast Treatment Reduces Pathological Fibrosis Following Myocardial Infarction
  • Fiona See, Masataka Watanabe, Andrew R. Kompa, Bing H. Wang, Andrew J. Boyle, Darren J. Kelly, Richard E. Gilbert, Henry Krum
| Articolo seguente Articolo seguente
  • Effect of Isoflavone on Balloon Catheter-Induced Neointimal Hyperplasia in Ovariectomised Rabbit Carotid Artery
  • Gai-Ying Zhang, Ren-Feng Qiu, Ying-Chun Sun, Le-Xin Wang

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.