Batteryless implantable dual-sensor capsule for esophageal reflux monitoring - 19/03/13

Doi : 10.1016/j.gie.2012.10.029 
Hung Cao, PhD 1, Smitha Rao, PhD 2, Shou-jiang Tang, MD 3, , Harry F. Tibbals, PhD 4, Stuart Spechler, MD 5, J.-C. Chiao, PhD 1, 5
1 Electrical Engineering Department, The University of Texas at Arlington, Arlington, Texas, USA 
2 Med-Worx, Grand Prairie, Texas, USA 
3 Department of Digestive Diseases, University of Mississippi Medical Center, Jackson, Mississippi, USA 
4 Materials Science and Engineering Department, The University of Texas at Arlington, Arlington, Texas, USA 
5 Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas, USA 

Reprint requests: Shou-jiang Tang, MD, Division of Digestive Diseases, Department of Internal Medicine, 2500 North State Street, Jackson, MS 39216

Riassunto

Background

Chronic GERD affects approximately 15% of adults in the United States and is one of the most prevalent clinical conditions involving the GI tract. The commercial tools for monitoring GERD include multichannel intraluminal impedance (MII) probes and pH-sensing capsules. However, MII probes cause discomfort, which alters patients' regular activities, whereas the pH-sensing capsule lacks the ability to detect weak or nonacid episodes, misses reflux episodes with similar pH values, and has a limited sampling rate and battery life.

Objective

To develop and test an implantable batteryless dual-sensor capsule that can be used to diagnose and monitor GERD.

Design

The implanted capsule is wirelessly powered by an external device. Simulated reflux episodes were created in 3 live porcine models. Impedance and pH data were continuously measured and recorded.

Intervention

The implant capsule was placed in the esophagus along with a commercial pH-sensing capsule for comparison.

Main Outcome Measurements

Precise impedance and pH readouts were obtained and compared with those from a commercial pH-sensing capsule.

Results

The wireless energy supplied by the external unit was strong enough to power the implant. The pH sensor accurately measured pH levels and the impedance sensor precisely located the reflux episodes.

Limitation

Simulated reflux events in a pig model.

Conclusion

Our wireless sensors are reliable in operation and provide accurate assessment of simulated reflux episodes. The entire device can potentially be used to diagnose and monitor GERD.

Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : BEST, MII, NG


Mappa


 DISCLOSURE: Smitha Rao was employed by Med-Worx. University of Texas at Arlington received a subcontract of a National Science Foundation SBIR grant from Med-Worx to J.-C. Chiao's research group for device design and telemetry characterization. The other authors disclosed no financial relationships relevant to this publication. Shou-jiang Tang, H. F. Tibbals, Stuart Spechler, and J.-C. Chiao were listed as the co-inventors of the reported technology. Certain aspects of this technology have been covered in intellectual property filed by the University of Texas Arlington and UT Southwestern.


© 2013  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 77 - N° 4

P. 649-653 - aprile 2013 Ritorno al numero
Articolo precedente Articolo precedente
  • Novel technique for submucosal tunneling and endoscopic resection of submucosal tumors (with video)
  • Mouen A. Khashab, Payal Saxena, Ali Kord Valeshabad, Yamile Haito Chavez, Faming Zhang, Venkata Akshintala, Gerard Aguila, Haruhiro Inoue, Pankaj J. Pasricha, Horst Neuhaus, Anthony N. Kalloo
| Articolo seguente Articolo seguente
  • A new instrument for endoscopic submucosal dissection (with videos)
  • Alexander Meining, Armin Schneider, Daniel Roppenecker, Tim Lüth

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.