Abbonarsi

Comparison between percutaneous and traditional fixation of lumbar spine fracture: Intraoperative radiation exposure levels and outcomes - 30/03/13

Doi : 10.1016/j.otsr.2012.12.012 
N. Bronsard a, , T. Boli a, M. Challali a, R. de Dompsure a, N. Amoretti b, B. Padovani b, G. Bruneton b, A. Fuchs c, F. de Peretti a
a Nice University Hospital Center, Orthopedic and Traumatologic Surgery Department, Hôpital Saint Roch, 5, rue Pierre-Dévoluy, 06000 Nice, France 
b Nice University Hospital Center, Medical Imaging Department, 5, rue Pierre-Dévoluy, 06000 Nice, France 
c Nice University Hospital Center, Radioprotection Department, 5, rue Pierre-Dévoluy, 06000 Nice, France 

Corresponding author. Tel.: +33 06 19 24 50 21; fax: +33 04 92 03 33 52.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Summary

Objective

To compare radiation exposure doses and clinical and radiological outcomes between percutaneous pedicular screwing (closed reduction internal fixation [CRIF]) and classical open reduction internal fixation (ORIF) in lumbar spine fracture without neurologic deficit.

Materials and methods

Sixty patients (mean age, 42.5years) were divided into two treatment groups: (Percutaneous) CRIF versus (traditional) ORIF. Screw position and anatomic vertebral reconstruction were checked on routine control X-ray and postoperative CT scan. Study parameters comprised: surgery time, radiation exposure time, radiation dose level for X-ray (DAP) and for CT (DLP),blood loss, length of hospital stay and postoperative pain (VAS).

Results

At a mean 25.5months’ follow-up,there were no significant inter-group differences on the epidemiological parameters: age, gender, fracture level, fracture type on the Magerl classification, preoperative local vertebral kyphosis angle, or fracture-to-surgery interval. Effective radiation dose was 3-fold higher in CRIF than in ORIF, but 6-fold lower than for the postoperative CT scan. Postoperative pain on VAS was significantly lower after CRIF, allowing earlier gait resumption and return to work and daily activity. There were no significant differences in length of hospital stay, patient satisfaction, screw malpositioning or postoperative or end-of-follow-up kyphosis angle.

Conclusion

Percutaneous surgery provided clinical and radiological outcomes strictly comparable to those of open surgery, but with a higher effective radiation exposure dose, including for the medical team and especially for the surgeon. This higher exposure dose, however, is to be relativized by comparison to that of the postoperative CT scan, which involved a much higher exposure dose for the patient.

Level of evidence

Level IV. Retrospective study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Radioprotection, Percutaneous spine surgery, Open spine surgery, Thoracolumbar spine fracture, Minimally invasive spine surgery


Mappa


© 2013  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 99 - N° 2

P. 162-168 - aprile 2013 Ritorno al numero
Articolo precedente Articolo precedente
  • Outcomes of anterior lumbar interbody fusion in low-grade isthmic spondylolisthesis in adults: A continuous series of 65 cases with an average follow-up of 6.6 years
  • G. Riouallon, C.-H.-F. Lachaniette, A. Poignard, J. Allain
| Articolo seguente Articolo seguente
  • Nefopam after total hip arthroplasty: Role in multimodal analgesia
  • F. Remérand, C. Le Tendre, P. Rosset, R. Peru, L. Favard, X. Pourrat, M. Laffon, J. Fusciardi

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.