Abbonarsi

CT dose optimisation and reduction in osteoarticular disease - 30/03/13

Doi : 10.1016/j.diii.2012.05.017 
A. Gervaise a, b, , P. Teixeira a, N. Villani c, S. Lecocq a, M. Louis a, A. Blum a
a Service d’imagerie Guilloz, hôpital central, CHU de Nancy, 29, avenue du Maréchal-de-Lattre-de-Tassigny, 54035 Nancy cedex, France 
b Service d’imagerie médicale, hôpital d’instruction des armées Legouest, 27, avenue de Plantières, BP 90001, 57077 Metz cedex 3, France 
c Unité de radiophysique médicale, centre Alexis-Vautrin, avenue de Bourgogne, 54511 Vandœuvre-lès-Nancy, France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

With an improvement in the temporal and spatial resolution, computed tomography (CT) is indicated in the evaluation of a great many osteoarticular diseases. New exploration techniques such as the dynamic CT and CT bone perfusion also provide new indications. However, CT is still an irradiating imaging technique and dose optimisation and reduction remains primordial. In this paper, the authors first present the typical doses delivered during CT in osteoarticular disease. They then discuss the different ways to optimise and reduce these doses by distinguishing the behavioural factors from the technical factors. Among the latter, the optimisation of the milliamps and kilovoltage is indispensable and should be adapted to the type of exploration and the morphotype of each individual. These technical factors also benefit from recent technological evolutions with the distribution of iterative reconstructions. In this way, the dose may be divided by two and provide an image of equal quality. With these dose optimisation and reduction techniques, it is now possible, while maintaining an excellent quality of the image, to obtain low-dose or even very low-dose acquisitions with a dose sometimes similar that of a standard X-ray assessment. Nevertheless, although these technical factors provide a major reduction in the dose delivered, behavioural factors, such as compliance with the indications, remain fundamental. Finally, the authors describe how to optimise and reduce the dose with specific applications in musculoskeletal imaging such as the dynamic CT, CT bone perfusion and dual energy CT.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Dose, Osteoarticular imaging, Optimisation, Reduction, CT


Mappa


© 2012  Éditions françaises de radiologie. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 94 - N° 4

P. 371-388 - aprile 2013 Ritorno al numero
Articolo precedente Articolo precedente
  • Radiologically guided percutaneous cryotherapy for soft tissue tumours: A promising treatment
  • F. Cornelis, M. Havez, N. Lippa, S. Al-Ammari, D. Verdier, T. Carteret, N. Amoretti, A. Gangi, J. Palussiere, O. Hauger, N. Grenier
| Articolo seguente Articolo seguente
  • Ultrasound-guided lymph node sampling in the initial management of breast cancer
  • C. Balu-Maestro, A. Ianessi, C. Chapellier, C. Marcotte, S. Stolear

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.