Durom hip resurfacing system: Retrospective study of 644 cases with an average follow-up of 34 months - 19/04/13

Doi : 10.1016/j.otsr.2012.10.018 
S. Leclercq a, M. Lavigne b, J. Girard c, , P. Chiron d, P.A. Vendittoli b
a St Martin Hospital Center, 18, rue Rocquemonts, 14000 Caen, France 
b Maisonneuve-Rosemont Hospital, 5415, L’Assomption Boulevard, H1T 2M4, Montreal, Quebec, Canada 
c Lille Regional University Hospital Center, Lille University Sports Medicine Unit, Orthopaedics C Department, 2, avenue Oscar-Lambret, 59037 Lille cedex, France 
d University Hospital of Rangueil, 1, avenue J.-Poulhès, TSA 50034, 31059 Toulouse cedex 9, France 

Auteur correspondant. Tel.: +33 3 20 44 68 28; fax: +33 3 20 44 66 07.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Summary

Introduction

The performance of second-generation metal-on-metal bearings has led to the reintroduction of hip resurfacing. The goal of this multicentre study was to evaluate the short-term radiological and clinical outcomes with the Durom hip resurfacing system.

Hypothesis

The Durom hip-resurfacing system will have similar results to other hip resurfacing systems and traditional hip arthroplasty implants.

Materials and methods

In the four participating centers, 580 patients (406 men, 174 women) and 644 hips were included. The average patient age was 48 years (range 16–77). A posterolateral surgical approach was used in 357 cases; a Hardinge-type approach was used in 182 cases and a Rottinger-type approach in 105.

Results

After an average follow-up of 34 months, 31 hips (4.8%) had been revised. The reasons for revision were the following: 10 (1.6%) neck fracture (seven with Rottinger operative approach, one with Hardinge approach and one with posterolateral approach); 12 (1.9%) femoral loosening (four with lateral approach and eight with posterolateral approach); four (0.6%) acetabular cup migration; three (0.5%) unexplained pain; one (0.2%) adverse reaction to metal debris; one (0.2%) infection. Four hips (0.6%) dislocated but without recurrence – all were operated using the Hardinge approach. The 613 hips that were not operated on again had satisfactory clinical results; the Merle d’Aubigné score was 17.2 (range 12–18) and the WOMAC score was 91 (range 20–100). The five-year survival rate was 91% (95% CI: 87–94%). Based on radiographs, the average cup inclination was 44.4° (range 30 to 70°). The femoral offset was reduced by an average of 2.4mm (−31 to 23mm) and the leg length had increased by an average of 0.8mm (−15 to 19mm) relative to the other side, which was prosthesis-free. None of the non-revised implants showed any signs of loosening.

Discussion

This multicentre evaluation revealed that the Durom revision rate was slightly higher than the rate with other hip resurfacing systems and traditional total hip arthroplasty. Although the Durom system displayed excellent tribological performance, the differences relative to other implants may be attributed to the challenges associated with impaction, related to the geometry and design of the cup, and to precarious primary fixation. The choice of surgical exposure and implantation technique was an important factor in the survival of the implant.

Level of proof

Level IV – Retrospective study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Hip, Resurfacing, Revision, Biomechanical reconstruction, Arthroplasty


Mappa


© 2013  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 99 - N° 3

P. 273-279 - maggio 2013 Ritorno al numero
Articolo precedente Articolo precedente
  • European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing
  • F. Hannemann, A. Hartmann, J. Schmitt, J. Lützner, A. Seidler, P. Campbell, C.P. Delaunay, H. Drexler, H.B. Ettema, E. García-Cimbrelo, H. Huberti, K. Knahr, J. Kunze, D.J. Langton, W. Lauer, I. Learmonth, C.H. Lohmann, M. Morlock, M.A. Wimmer, L. Zagra, K.P. Günther
| Articolo seguente Articolo seguente
  • Acetabular fracture: Long-term follow-up and factors associated with secondary implantation of total hip arthroplasty
  • B. Dunet, C. Tournier, A. Billaud, N. Lavoinne, T. Fabre, A. Durandeau

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.