Abbonarsi

In normal knees, joint space width (JSW) is correlated with the intermargin distance (IMD), a measure of medial tibial plateau alignment. Variations in IMD explain variability in JSW in serial radiographs - 30/05/13

Doi : 10.1016/j.jbspin.2012.07.006 
Catherine Mercier a, b, c, Muriel Piperno a, , Eric Vignon a, Kenneth Brandt d, Marc Hochberg e, Marie-Pierre Hellio Le Graverand f
a Universite Claude-Bernard Lyon-1, Lyon, France 
b Hospices Civils de Lyon, Service de Biostatistique, 69003 Lyon, France 
c CNRS, UMR5558, Laboratoire de Biométrie et Biologie Evolutive, Equipe Biostatistique Santé, 69622 Villeurbanne, France 
d University of Kansas Medical Center, Kansas City, KS, USA 
e University of Maryland School of Medicine, Baltimore, MD, USA 
f Pfizer Global Research and Development, New London, CT, USA 

Corresponding author. Centre Hospitalier Lyon Sud, 69495 Pierre Benite, France. Tél.: +33 47 88 61 688; Fax: +33 47 88 66 540.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 5
Iconografia 4
Video 0
Altro 0

Abstract

Objective

To ascertain the importance of alignment of the medial tibial plateau (MTP), as determined by the distance between the anterior and posterior margins of the plateau (intermargin distance [IMD]), for measurements of joint space width (JSW) in radiographs of normal knees.

Methods

JSW and IMD were measured in paired baseline and 12-month knee films of 122 subjects from the osteoarthritis initiative (OAI). Relationships between JSW and IMD, and between the variation in JSW and variation in IMD, were evaluated.

Results

In cross-sectional analysis, a non-linear relationship existed between JSW and the concurrent IMD. With poor MTP alignment (IMD>1.7mm), a 1.0-mm increase in IMD resulted in a 0.16-mm (95%CI: 0.11–0.21) increase in JSW (P<0.0001). In a longitudinal analysis, the effect of IMD variation on variation in JSW was also highly significant (P<0.0001). A variation of 1mm between IMDBaseline and IMD12month was associated with a 0.10-mm (95% CI: 0.06–0.13) variation in JSW, with variations in JSW and IMD occurring in the same direction. An IMD variation less than or equal to 1.0mm was determined to be acceptable for accurate evaluation of JSW in serial radiographs.

Conclusion

The error in measurement of JSW caused by variation in IMD in serial radiographs of normal knees can be as large, or larger, than the mean rate of 12-month joint space narrowing (JSN) in OA knees. MTP alignment and replication of alignment in serial knee films are required for accurate determination of JSN in OA knee.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Knee osteoarthritis, Joint space measurement, Tibial plateau alignment, Standardized radiography


Mappa


© 2012  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 80 - N° 2

P. 183-187 - marzo 2013 Ritorno al numero
Articolo precedente Articolo precedente
  • Efficacy of anakinra in calcium pyrophosphate crystal-induced arthritis: A report of 16 cases and review of the literature
  • Sébastien Ottaviani, Lauren Brunier, Jean Sibilia, François Maurier, Marc Ardizzone, Daniel Wendling, Ghislaine Gill, Elisabeth Palazzo, Olivier Meyer, Philippe Dieudé
| Articolo seguente Articolo seguente
  • Loss of sympathetic nerve fibers in vital intertrochanteric bone cylinders lateral to osteonecrosis of the femoral head
  • Johannes Beckmann, Matthias Knödl, Eva Bauser, Markus Tingart, Joachim Grifka, Rainer H. Straub

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.