Summary

Background

Lower extremity alignment correlates with native femoral offset. Eventual impact of the change in femoral offset induced by total hip arthroplasty (THA) on lower extremity alignment has not been documented.

Hypothesis

THA significantly changes lower extremity alignment, and the change correlates with the change in femoral offset.

Materials and methods

We conducted a prospective study of 200 patients with primary hip osteoarthritis or avascular femoral head necrosis who underwent cementless THA. Pre-operative computed-tomography templating was performed and the femoral component was then custom-manufactured to replicate the native femoral anatomy. Mean age was 58 years (range, 28–83 years). Before and at least two years after THA, two observers who were not involved in the surgical procedures used standing antero-posterior long-leg radiographs to determine the mechanical axis of the lower-limb (hip-knee-ankle [HKA] angle), femoral offset, neck-shaft angle (NSA), and lower-limb length discrepancy (LLLD).

Results

Mean values pre-operatively and at last follow-up were as follows: HKA angle, 179.2°±3.9° (range, 170.5° to 190.5°) and 177.7°±3.5°(range, 173° to 187°); LLLD, −0.7mm (range, –30mm to+25mm) and+5.1mm (range, –7mm to+21mm); NSA, 134°±7.5° (range, 100° to 124°) and 135°±4.2° (range, 124° to 146°); and femoral offset, 42±7.8mm (range, 24mm to 68mm) and 49±7.5mm (range, 33mm to 70mm). Although THA significantly altered lower-limb alignment, univariate and multivariate analyses showed no significant association between the change in HKA angle and the change in femoral offset.

Discussion

Lower-limb alignment was significantly affected by THA, although the HKA angle changes were small. The small impact of THA on HKA angle values may be ascribable to efforts aimed at replicating the native femoral offset during arthroplasty, as well as to the limited sample size and to potential measurement errors related to the small size of the changes. Our results suggest that, provided careful attention is directed to replicating the native femoral offset, THA in patients with limited pre-operative anatomical abnormalities may have no major impact on the biomechanical parameters of the ipsilateral knee.

Level of evidence

Level III, prospective diagnostic study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Total hip arthroplasty, Femoral offset, Lower extremit alignment, Adult, Biomechanics


Mappa


© 2013  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 99 - N° 5

P. 493-500 - settembre 2013 Ritorno al numero
Articolo precedente Articolo precedente
  • Contents
| Articolo seguente Articolo seguente
  • The lateral view head-neck index (LVHNI): A diagnostic tool for the sequelae of slipped capital femoral epiphysis
  • J. Murgier, P. Chiron, E. Cavaignac, A. Espié, X. Bayle-Iniguez, B. Lepage

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.