Abbonarsi

Do bone loss and reconstruction procedures differ at revision of cemented unicompartmental knee prostheses according to the use of metal-back or all-polyethylene tibial component? - 02/10/13

Doi : 10.1016/j.otsr.2013.03.018 
T. Rouanet a, b, , A. Combes a, b, H. Migaud a, b, G. Pasquier a, b
a Université Lille Nord de France, 59000 Lille, France 
b Services d’orthopédie, département universitaire de chirurgie orthopédique, université Lille 2, hôpital Salengro, CHRU de Lille, place de Verdun, 59037 Lille cedex, France 

Corresponding author. Academic Department Orthopaedic Surgery, Lille 2 University, Roger Salengro Hospital, Lille Teaching Regional Hospital Center, Place de Verdun, 59037 Lille, France. Tel.: +33 03 20 44 68 28; fax: +33 03 20 44 66 07.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Summary

Introduction

Results of unicompartmental knee arthroplasty (UKA) revision are known but the severity of bone loss and the need for reconstruction are not detailed for different tibial implants.

Hypothesis

Metal-backing UKA revision exposes the patient to more severe tibial bone loss and requires more substantial reconstruction procedures than cemented polyethylene UKA revision.

Materials and methods

This retrospective series of 23 revisions of UKA to total knee arthroplasty (TKA) compared 11 all-polyethylene UKAs with 12 metal-backing UKAs. Factors that contributed to failure were aseptic loosening (n=12) and osteoarthritis evolution (n=11). Both groups were similar regarding the demographic and clinical features. We reported bone loss and the reconstruction procedure to fill it according to the initially used tibial implant. The results were evaluated with the IKS score to a follow-up of 37months (range, 24–67months).

Results

There were more tibial segmental bone loss (10 versus 3) and more metal wedges (8/12 versus 2/11) in metal-backing UKA revision (P<0.05). Tibial stems were more often used in metal-backing UKA revision (12/12 versus 7/11) (P=0.04). The results of TKA at follow-up did not differ according to whether the revised tibial implant was all polyethylene (IKS=155 [range, 107–195]) or metal-back (IKS=155 [range, 127–172]).

Discussion

This study suggests that metal-backing UKA revision exposes the patient to more severe tibial bone loss requiring more substantial reconstruction. These results must be confirmed on a larger population, but surgeons should be alerted to this kind of revision surgery, which warrants having available a revision knee prothesis.

Level of evidence

Level III, case-control study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Unicompartmental knee prosthesis, Revision, Bone loss, Reconstruction


Mappa


© 2013  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 99 - N° 6

P. 687-692 - ottobre 2013 Ritorno al numero
Articolo precedente Articolo precedente
  • Outcomes of 447 SCORE® highly congruent mobile-bearing total knee arthroplasties after 5–10 years follow-up
  • F. Châtain, T.H. Gaillard, S. Denjean, O. Tayot
| Articolo seguente Articolo seguente
  • Reduction plasty for hypertrophic anterior cruciate ligament mucoid degeneration: Clinical and knee laxity outcomes in 23 cases
  • A. Morice, A. Coupry, F. Lintz, H. Robert

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.