Abbonarsi

Selective Laser Trabeculoplasty Following Failed Combined Phacoemulsification Cataract Extraction and Ab Interno Trabeculectomy - 23/10/13

Doi : 10.1016/j.ajo.2013.05.044 
Marc Töteberg-Harms, Douglas J. Rhee
 Massachusetts Eye & Ear Infirmary, Harvard Medical School, Boston, Massachusetts 

Inquiries to Douglas J. Rhee, Massachusetts Eye & Ear Infirmary, Harvard Medical School, 243 Charles Street, Boston, MA 02114

Abstract

Purpose

To assess the effect of selective laser trabeculoplasty (SLT) following failed phacoemulsification cataract extraction combined with ab interno trabeculectomy (AIT) using the Trabectome (phaco-trabectome).

Design

Randomized, interventional case series.

Methods

Retrospectively, the medical records of patients who underwent SLT between March 2010 and July 2012 by 1 surgeon at a single center after a failed phaco-AIT were evaluated. Inclusion criteria were age ≥18 years with no upper limit and prior failed phaco-AIT attributable to glaucoma progression. Exclusion criterion was performance of any additional glaucoma procedure with influence on intraocular pressure (IOP) during follow-up and a follow-up after surgery of <3 months. Success was defined by reduction of IOP of >3 mm Hg and 20% and number of antiglaucoma medications equal to or less than baseline. Main outcome measures were IOP, antiglaucoma medications, time to failure, and Kaplan-Meier survival curve.

Results

Fourteen eyes of 13 subjects were included. Mean follow-up after SLT was 12.9 ± 8.7 months. Total laser energy was 59.5 ± 8.7 mJ. Baseline IOP was 17.9 ± 3.3 mm Hg and number of antiglaucoma medications at baseline was 2.0 ± 1.0. All SLT procedures failed. Median time to failure after SLT was 3.6 ± 0.8 (range 2.1-5.1) months. Number of antiglaucoma medications did not change.

Conclusions

In eyes in which the IOP was no longer controlled following phaco-trabectome, SLT had a limited duration of significant IOP-lowering effect. Other alternatives, such as incisional filtration surgery, should be considered following failed phaco-trabectome.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2013  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 156 - N° 5

P. 936 - novembre 2013 Ritorno al numero
Articolo precedente Articolo precedente
  • Clinical Results of Ab Interno Trabeculotomy Using the Trabectome for Open-Angle Glaucoma: The Mayo Clinic Series in Rochester, Minnesota
  • Yachna Ahuja, Son Ma Khin Pyi, Mehrdad Malihi, David O. Hodge, Arthur J. Sit
| Articolo seguente Articolo seguente
  • Intraocular Pressure Fluctuation During Microincision Vitrectomy With Constellation Vision System
  • Yoshimi Sugiura, Fumiki Okamoto, Yoshifumi Okamoto, Takahiro Hiraoka, Tetsuro Oshika

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.