Abbonarsi

Which dose for what image? Iterative reconstruction for CT scan - 09/11/13

Doi : 10.1016/j.diii.2013.03.008 
J. Greffier , A. Fernandez, F. Macri, C. Freitag, L. Metge, J.-P. Beregi
 Medical Imaging and Radiology, EA2415, Université Montpellier-Nîmes, CHU de Carémeau, boulevard du Professeur-Robert-Debré, 30029 Nîmes cedex 9, France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Purpose

To evaluate the potential of iterative reconstruction for reducing the dose given to the patient during abdominal CT scanning.

Materials and methods

A double abdominal CT scan acquisition (Somatom Definition AS+ Siemens) performed without contrast administration at –30% and at –70% of the doses (mAs) was compared to the standard acquisition in 10 patients. The raw data were reconstructed by filtered back projection (FBP) and using the SAFIRE iterative reconstruction method (five levels of iteration). The signal, noise, signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) were compared for three regions of interest, including the kidney, psoas and abdominal fat.

Results

The signal in each region of interest was not modified based on the type of reconstruction. The noise level decreased significantly during the passage from the FBP to SAFIRE, as well as with the increase in the SAFIRE level. The SNR and CNR therefore increased with the use of iterative reconstructions. The increase in noise observed between the acquisition at –30% and that at –70% was compensated by the use of higher SAFIRE levels.

Conclusion

Iterative reconstructions can be used to improve the SNR and CNR at a constant dose or to reduce the dose by keeping the same SNR and CNR on abdominal CT images.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : CT scan, Irradiation, Iterative reconstruction, Dose, X-rays


Mappa


© 2013  Éditions françaises de radiologie. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 94 - N° 11

P. 1117-1121 - novembre 2013 Ritorno al numero
Articolo precedente Articolo precedente
  • Emergency ultrasound: A prospective study on sufficient adequate training for military doctors
  • N. Cazes, F. Desmots, Y. Geffroy, A. Renard, J. Leyral, K. Chaumoître
| Articolo seguente Articolo seguente
  • Accuracy of multi-detector computed tomographic angiography assisted by post-processing software for diagnosis atheromatous renal artery stenosis
  • O. Pellerin, M. Sapoval, L. Trinquart, A. Redheuil, A. Azarine, G. Chatellier, E. Mousseaux

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.