Automatic Optimization of Cardiac Resynchronization Therapy Using SonR—Rationale and Design of the Clinical Trial of the SonRtip Lead and Automatic AV-VV Optimization Algorithm in the Paradym RF SonR CRT-D (RESPOND CRT) Trial - 22/03/14

Doi : 10.1016/j.ahj.2013.12.007 
Josep Brugada, MD, PhD a, , Johannes Brachmann, MD b, Peter Paul Delnoy, MD, PhD c, Luigi Padeletti, MD, PhD d, Dwight Reynolds, MD e, Philippe Ritter, MD f, Alberto Borri-Brunetto, MSc g, Jagmeet P. Singh, MD, PhD h
a Hospital Clinic, University of Barcelona, Barcelona, Spain 
b Coburg Hospital, Coburg, Germany 
c Isala Kliniken, Zwolle, The Netherlands 
d Careggi University Hospital, Florence, Italy 
e University of Oklahoma, Oklahoma City, OK 
f University Hospital of Bordeaux, Pessac, France 
g Sorin CRM SAS, Clamart, France 
h Massachusetts General Hospital, Boston, MA 

Reprint requests: Josep Brugada MD, PhD, Hospital Clinic, University of Barcelona, Barcelona, Spain.

Riassunto

Although cardiac resynchronization therapy (CRT) is effective in most patients with heart failure (HF) and ventricular dyssynchrony, a significant minority of patients (approximately 30%) are non-responders. Optimal atrioventricular and interventricular delays often change over time and reprogramming these intervals might increase CRT effectiveness. The SonR algorithm automatically optimizes atrioventricular and interventricular intervals each week using an accelerometer to measure change in the SonR signal, which was shown previously to correlate with hemodynamic improvement (left ventricular [LV] dP/dtmax). The RESPOND CRT trial will evaluate the effectiveness and safety of the SonR optimization system in patients with HF New York Heart Association class III or ambulatory IV eligible for a CRT-D device. Enrolled patients will be randomized in a 2:1 ratio to either SonR CRT optimization or to a control arm employing echocardiographic optimization. All patients will be followed for at least 24 months in a double-blinded fashion. The primary effectiveness end point will be evaluated for non-inferiority, with a nested test of superiority, based on the proportion of responders (defined as alive, free from HF-related events, with improvements in New York Heart Association class or improvement in Kansas City Cardiomyopathy Questionnaire quality of life score) at 12 months. The required sample size is 876 patients. The two primary safety end points are acute and chronic SonR lead-related complication rates, respectively. Secondary end points include proportion of patients free from death or HF hospitalization, proportion of patients worsened, and lead electrical performance, assessed at 12 months. The RESPOND CRT trial will also examine associated reverse remodeling at 1 year.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-No Derivative Works License, which permits non-commercial use, distribution, and reproduction in any medium, provided the original author and source are credited.
 RCT# NCT01534234.


© 2014  The Authors. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 167 - N° 4

P. 429-436 - aprile 2014 Ritorno al numero
Articolo precedente Articolo precedente
  • Cardiovascular drugs that increase the risk of new-onset diabetes
  • Kwok Leung Ong, Philip J. Barter, David D. Waters
| Articolo seguente Articolo seguente
  • Design and rationale for the Prevention of Cardiovascular Events in Patients With Prior Heart Attack Using Ticagrelor Compared to Placebo on a Background of Aspirin–Thrombolysis in Myocardial Infarction 54 (PEGASUS-TIMI 54) trial
  • Marc P. Bonaca, Deepak L. Bhatt, Eugene Braunwald, Marc Cohen, Philippe Gabriel Steg, Robert F. Storey, Peter Held, Eva C. Jensen, Marc S. Sabatine

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.