Acute echocardiographic optimization of multiple stimulation configurations of cardiac resynchronization therapy through quadripolar left ventricular pacing: A tailored approach - 22/03/14

Doi : 10.1016/j.ahj.2013.12.028 
Leonardo Calò, MD, FESC ⁎ , Annamaria Martino, MD, Ermenegildo de Ruvo, MD, Monia Minati, MD, Simona Fratini, MD, PhD, Marco Rebecchi, MD, Chiara Lanzillo, MD, PhD, Alessandro Fagagnini, MD, Alessio Borrelli, MD, Lucia De Luca, MD, PhD, Luigi Sciarra, MD
 Division of Cardiology, Policlinico Casilino, ASL Rome B, Rome, Italy 

⁎Reprint requests: Leonardo Calò, MD, FESC, Via Buonarroti 16, 00047 Marino, Rome, Italy.

Riassunto

Background

Cardiac resynchronization therapy (CRT) is ineffective in approximately 30% of recipients, in part due to sub-optimal left ventricular (LV) pacing location. The Quartet LV lead, with 2 additional electrodes proximal to conventional bipolar lead electrodes, enables 10 different pacing configurations at four independent LV locations. In a CRT patient cohort, we sought to evaluate the spectrum of echocardiographic and electrocardiographic response over these 10 configurations, to select the optimal one in each patient. Moreover, we sought to evaluate the 6-months clinical and echocardiographic response to a “tailored approach” in which the optimal LV pacing configuration for CRT was determined by echocardiographic measures, QRSd and pacing capture thresholds.

Methods

Twenty-two consecutive CRT indicated patients were implanted with a quadripolar CRT system (St. Jude Medical). Optimal LV pacing configuration was determined by echocardiographic measures, including velocity time integral (VTI), myocardial performance index (MPI) and mitral regurgitation (MR), and an electrocardiographic measure (QRS duration) during pacing from each of the configurations at pre-discharge. The optimal LV pacing vector was chosen for every patient. Clinical and echocardiographic assessment was repeated after 6 months.

Results

Various configurations provided different VTI, MPI, MR and QRSd values. Conventional bipolar vectors (ie, D1-M2, D1-RVc, M2-RVc) were rarely associated with the best echocardiographic improvements and provided significantly worse VTI, MR, MPI, and QRSd values than the best configuration for every patient (P = .005, P = .05 and P = .03 for VTI; P = .01, P = .005 and P = .001 for MPI; P = .003, P = .01 and P = .005 for MR, P > .5, P = .01 and P = .05 for QRSd) Conversely, “unconventional” proximal configurations (ie, making use of P4 and M3 electrodes) were generally characterized by higher acute VTI, MR and MPI improvements. CRT devices were reprogrammed with an “unconventional” LV pacing configuration in 50% of patients. A significant improvement in New York Heart Association class (81%), LV ejection fraction (76%), end-diastolic and end-systolic volumes was observed after 6 months (P = .02, P < .001, P = .02 and P = .003, respectively).

Conclusions

In this study, conventional bipolar vectors of quadripolar-CRT were rarely associated with the best echocardiographic improvements. Quadripolar CRT utilizing optimal LV pacing configuration was associated with a significant improvement in New York Heart Association class and LV ejection fraction after 6 months.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2014  Mosby, Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 167 - N° 4

P. 546-554 - aprile 2014 Ritorno al numero
Articolo precedente Articolo precedente
  • Scar tissue–guided left ventricular lead placement for cardiac resynchronization therapy in patients with ischemic cardiomyopathy: An acute pressure-volume loop study
  • Gerben Jan de Roest, LiNa Wu, Carel C. de Cock, Matthijs L. Hendriks, Peter Paul H.M. Delnoy, Albert C. van Rossum, Cornelis P. Allaart
| Articolo seguente Articolo seguente
  • Ventricular geometric characteristics and functional benefit of mild right ventricular outflow tract obstruction in patients with significant pulmonary regurgitation after repair of tetralogy of Fallot
  • Chun-An Chen, Ssu-Yuan Chen, Jou-Kou Wang, Wen-Yih Isaac Tseng, Hsin-Hui Chiu, Chung-I Chang, Ing-Sh Chiu, Yih-Sharng Chen, Ming-Chun Yang, Chun-Wei Lu, Ming-Tai Lin, Mei-Hwan Wu

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.