Abbonarsi

Same-Day Intrastromal Corneal Ring Segment and Collagen Cross-Linking for Ectasia after Laser In Situ Keratomileusis: Long-Term Results - 16/04/14

Doi : 10.1016/j.ajo.2014.02.011 
Aydin Yildirim a, ⁎ , Hasim Uslu a, Necip Kara b, Hanefi Cakir c, Bulent Gurler a, Hatice Nur Colak a, Engin Bilge Ozgurhan d
a Department of Ophthalmology, Fatih University Medical Faculty Hospital, Istanbul, Turkey 
b Department of Ophthalmology, Gaziantep Sehitkamil State Hospital, Istanbul, Turkey 
c Turkiye Hospital Eye Clinic, Istanbul, Turkey 
d Department of Ophthalmology, Beyoglu Eye Education and Research Hospital, Istanbul, Turkey 

∗Inquiries to Aydin Yildirim, Fatih University Medical Faculty Hospital, Istanbul, Turkey

Abstract

Purpose

To report the long-term results of combined same-day intrastromal corneal ring segment placement and corneal collagen cross-linking (CXL) for postoperative laser in situ keratomileusis (LASIK) ectasia.

Design

Retrospective, interventional case series.

Method

This retrospective, interventional cases series was performed in Turkiye Hospital Eye Clinic and the Department of Ophthalmology, Fatih University Medical Faculty Hospital, Istanbul, Turkey. Sixteen eyes of 14 patients with postoperative ectasia after LASIK were enrolled. All consecutive patients were treated with femtosecond laser-assisted intrastromal corneal ring segment implantation and followed by same-day corneal collagen cross-linking for ectasia occurring after LASIK. Main outcome measures included uncorrected distance visual acuity, corrected distance visual acuity, spherical and cylindrical refraction, and simulated keratometry values.

Results

The mean age ± standard deviation of the 10 women and 4 men was 33.0 ± 6.5 years (range, 23 to 44 years), and the mean follow-up was 43 months (range, 36 to 62 months). The uncorrected distance visual acuity improved significantly from 1.18 ± 0.42 logarithm of the minimal angle of resolution (logMAR) units to 0.44 ± 0.22 logMAR (P < .001), and the corrected distance visual acuity improved significantly from 0.46 ± 0.26 logMAR to 0.21 ± 0.14 logMAR (P < .001). The mean spherical and cylindrical refraction decreased significantly (P < .001 for both). The maximum keratometry value decreased from baseline by 49.3 ± 4.9 diopters (D) to 43.9 ± 2.8 D at the last visit, and the minimum keratometry value decreased from 44.3 ± 4.7 D to 41.5 ± 3.5 D (P < .001 for both). No serious complications were shown during follow-up.

Conclusions

Implantation of intrastromal corneal ring segment implantation combined with same-day corneal collagen cross-linking was a safe and effective treatment for ectasia occurring after LASIK. It also significantly improved the visual acuity, refraction, and keratometry values.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2014  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 157 - N° 5

P. 1070 - maggio 2014 Ritorno al numero
Articolo precedente Articolo precedente
  • Whole Eye Axial Biometry During Accommodation Using Ultra-long Scan Depth Optical Coherence Tomography
  • Jianguang Zhong, Aizhu Tao, Zhe Xu, Hong Jiang, Yilei Shao, Huicheng Zhang, Che Liu, Jianhua Wang
| Articolo seguente Articolo seguente
  • Aberrometry in Patients Implanted With Accommodative Intraocular Lenses
  • Pablo Pérez-Merino, Judith Birkenfeld, Carlos Dorronsoro, Sergio Ortiz, Sonia Durán, Ignacio Jiménez-Alfaro, Susana Marcos

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.