Abbonarsi

Distal volar radial plates: How anatomical are they? - 10/05/14

Doi : 10.1016/j.otsr.2013.11.014 
S. Evans a, , A. Ramasamy a, b, S.C. Deshmukh a
a Department of Trauma and Orthopaedics, City Hospital, Dudley Road, Birmingham, B18 7QH, United Kingdom 
b The Royal British Legion Centre for Blast Injury Studies, Imperial College London, South Kensington, London SW7 2BW, United Kingdom 

Corresponding author. Tel.: +07888714264.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background

Fractures of the distal radius are common, with volar locking plates being increasingly used in their treatment. They aim to provide stable internal fixation and are designed to mirror the natural anatomy. Current volar plate designs incorporate a volar cortical angle (VCA) of 25 degrees.

Hypothesis

The aim of this study is to determine whether the VCA in uninjured distal radii corresponds accurately with modern volar plate designs.

Materials and Methods

A retrospective radiological analysis utilizing Computed Tomography scans to assess the VCA of 100 distal radii. Each distal radius was subjected to 3 measurements of the VCA in the sagittal plane.

Results

One hundred patients were identified (67 male, 33 female; mean age 37.4 years). The mean VCA was 32.9 degrees (S.D.±5.14 degrees). The VCA in male patients was significantly greater than in females (33.6 vs 31.5 degrees; P=0.04). There was a statistically significant difference between the lateral VCA and medial VCA (32.2 vs 34.3 degrees, P=0.02).

Discussion

Our study clearly demonstrates that the VCA measured in the distal radius is significantly greater than the volar angulation incorporated within modern plate design. Given that the aim of ORIF is to anatomically reconstruct the distal radius, our study highlights that this may not be possible with current plates.

Levels of evidence

Level IV Retrospective case series.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Distal radius fracture, Volar locking plates, ORIF, Anatomical reconstruction, CT, Biomechanics


Mappa


© 2014  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 100 - N° 3

P. 293-295 - maggio 2014 Ritorno al numero
Articolo precedente Articolo precedente
  • Ultra minimally invasive sonographically guided carpal tunnel release: An external pilot study
  • A. Capa-Grasa, J.M. Rojo-Manaute, F.C. Rodríguez, J.V. Martín
| Articolo seguente Articolo seguente
  • Lateral meniscus allograft transplantation: Clinical and anatomic outcomes after arthroscopic implantation with tibial tunnels versus open implantation without tunnels
  • B. Faivre, P. Boisrenoult, G. Lonjon, N. Pujol, P. Beaufils

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.