Abbonarsi

Comparing Cardiopulmonary Exercise Testing in Severe COPD Patients with and without Pulmonary Hypertension - 18/09/14

Doi : 10.1016/j.hlc.2013.12.015 
Wilawan Thirapatarapong, MD a, b, , Hilary F. Armstrong, MS b , Matthew N. Bartels, MD c
a Department of Rehabilitation Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700 Thailand 
b Department of Rehabilitation and Regenerative Medicine, Columbia University Medical Center, NY, NY 10032 USA 
c Department of Rehabilitation Medicine, Albert Einstein College of Medicine and Montefiore Medical Center, Bronx, NY 10467 USA 

Corresponding author at: Department of Rehabilitation Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700 Thailand. Tel.: +662-419-7508; fax: +662-411-4813.

Riassunto

Purpose

To determine; (i) the effect of PH on exercise capacity, gas exchange and oxygen pulse; (ii) the variables that correlate with mean pulmonary artery pressure (mPAP) in severe COPD patients.

Methods

We reviewed 98 severe COPD patients who had pulmonary function, right heart catheterisation, and cardiopulmonary exercise testing (CPET) performed within six months of each other. PH was defined by a resting mPAP > 25mmHg. COPD patients with and without PH were compared using the independent samples t-test and Mann-Whitney U test. Pearson correlation coefficients were used to assess the relationship between continuous variables.

Results

PH was present in 32% of patients and the majority of PH was mild (mPAP, 25-35mmHg). Peak workload, oxygen uptake and oxygen pulse on CPET were significantly lower in the PH group. Mean PAP was found to inversely correlate with peak oxygen uptake, with a tendency towards lower six-minute walk distance. No difference between two groups was seen in any of the gas exchange variables.

Conclusion

In severe COPD, there is a relatively high percentage of PH which causes a decrease in exercise capacity and oxygen pulse without significantly altered ventilation as measured by CPET. Lower than expected exercise performance without a change in pulmonary function may indicate a need for evaluation for possible PH.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Pulmonary hypertension, COPD, Cardiopulmonary exercise testing, Exercise capacity, Gas exchange


Mappa


© 2014  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 23 - N° 9

P. 833-840 - settembre 2014 Ritorno al numero
Articolo precedente Articolo precedente
  • Effect of Smoking on Tp-e Interval, Tp-e/QT and Tp-e/QTc Ratios as Indices of Ventricular Arrhythmogenesis
  • Hakan Ta?olar, Mehmet Ball?, Adil Bayramo?lu, Y?lmaz Ömür Otlu, Mustafa Çetin, Burak Altun, Musa Çak?c?
| Articolo seguente Articolo seguente
  • Aortic Valve Replacement in Octogenarians
  • Jessica A. Ditchfield, Emily Granger, Phillip Spratt, Paul Jansz, Kumud Dhital, Alan Farnsworth, Chris Hayward

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.