Abstract

Introduction

The precision of bone cuts and the positioning of components influence the functionality and longevity of total knee arthroplasty (TKA). The objective of this study was to evaluate the results of TKA, performed after 3D preoperative templating, with the prosthesis implanted using custom cutting guides (Knee-Plan® system, Symbios Orthopédie SA).

Material and methods

This prospective study investigated 107 TKAs. Three-dimensional preoperative templating was carried out on the surface views and CT views to analyze the deformation of the lower limb and plan the implantation. The components were positioned in an individualized manner to realign the lower limb and provide ligament balance based on bone landmarks. Final component positioning was analyzed in the three planes with a postoperative CT scan. The preoperative and 1 year follow-up IKS and WOMAC scores were collected and compared.

Results

All the cutting guides were stable and functional. Femoral component planning was reproduced with 0±2 precision in the frontal plane (94%±3), 2±3 in the sagittal plane, and 0±2 in the transverse plane. The precision of the tibial component was reproduced with 0±2 precision in the frontal plane (93%±3) and 0±4 in the sagittal plane. The HKA angle increased from 177±7 preoperatively to 180±3 at 1 year of follow-up. The IKS and WOMAC scores were significantly improved at 1 year (P<0.0001).

Conclusion

The Knee-Plan® system can be a realistic, simple, and reliable alternative to conventional cutting guides and to computer-assisted surgery for TKA implantation.

Level of evidence

IV; prospective cohort study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Total knee arthroplasty, Patient-specific 3D preoperative templating, Custom cutting guides, CTscan


Mappa


© 2014  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 100 - N° 6S

P. S281-S286 - ottobre 2014 Ritorno al numero
Articolo precedente Articolo precedente
  • Influence of socioprofessional category on the duration of sick leave after hallux surgery. A prospective study of 102 cases
  • W. Graff, D. Biau, Q. Manach, French Association of Foot Surgery (AFCP) c
| Articolo seguente Articolo seguente
  • The reliability of the anterior pelvic plane for computer navigated acetabular component placement during total hip arthroplasty: Prospective study with the EOS imaging system
  • O. Barbier, W. Skalli, L. Mainard, D. Mainard, Computer Assisted Orthopedic Surgery–France (CAOS-France) Professeur E. Stindel, service orthopédie traumatologie, CHU de Brest, hôpital de la Cavale-Blanche, boulevard Tanguy-Prigent, 29609 Brest cedex, France

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.