Abbonarsi

Robotic phrenic nerve harvest: A feasibility study in a pig model - 11/10/14

Doi : 10.1016/j.main.2014.07.006 
P. Porto de Melo a, b, c, H. Miyamoto d, e, T. Serradori f, G. Ruggiero Mantovani g, J. Selber h, S. Facca d, W.-D. Xu i, N. Santelmo j, P. Liverneaux d,
a Center for Advanced Studies in Orthopedics and Neurosurgery, São Paulo, Brazil 
b Neurosurgery Department, São Paulo Military Área Hospital, Brazilian Army, São Paulo, Brazil 
c Institute of Education and Sciences, German Hospital Oswaldo Cruz, São Paulo, Brazil 
d Department of Hand Surgery, Strasbourg University Hospitals, FMTS, Strasbourg University, 10, avenue Baumann, 67403 Illkirch cedex, France 
e Department of Orthopaedic Surgery, University of Tokyo, Tokyo, Japan 
f General and digestive Departement, University Hospital of Nancy, 54511 Nancy, France 
g São Paulo Hand Center, Hospital Beneficência Portuguesa de São Paulo, São Paulo, Brazil 
h MD Anderson Center, Houston, TX, USA 
i Department of Hand Surgery, Huashan Hospital, Fudan University, Shanghai, China 
j Department of Thoracic Surgery, Strasbourg University Hospitals, FMTS, Strasbourg University, 1, place de l’Hôpital, 67000 Strasbourg cedex, France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 5
Iconografia 3
Video 0
Altro 0

Abstract

The aim of this study was to report on the feasibility of robotic phrenic nerve harvest in a pig model. A surgical robot (Da Vinci S™ system, Intuitive Surgical®, Sunnyvale, CA) was installed with three ports on the pig's left chest. The phrenic nerve was transected distally where it enters the diaphragm. The phrenic nerve harvest was successfully performed in 45 minutes without major complications. The advantages of robotic microsurgery for phrenic nerve harvest are the motion scaling up to 5 times, elimination of physiological tremor, and free movement of joint-equipped robotic arms. Robot-assisted neurolysis may be clinically useful for harvesting the phrenic nerve for brachial plexus reconstruction.

Il testo completo di questo articolo è disponibile in PDF.

Résumé

Le but de cette étude était de rapporter la faisabilité du prélèvement du nerf phrénique avec un robot sur un modèle porcin. Un robot chirurgical (système da Vinci S™, Intuitive Surgical®, Sunnyvale, CA) a été installé avec trois trocarts sur l’hémithorax gauche d’un cochon. Le nerf phrénique a été sectionné distalement, là où il pénètre dans le diaphragme. Le prélèvement du nerf phrénique a été réalisé avec succès en 45 minutes sans complications majeures. Les avantages de la microchirurgie robotisée pour le prélèvement du nerf phrénique sont la mise à l’échelle du mouvement jusqu’à 5 fois, l’élimination de tremblement physiologique, et la liberté de mouvements des articulations des bras robotiques. La neurolyse robot-assistée peut être cliniquement utile pour le prélèvement du nerf phrénique dans la chirurgie de réparation des lésions du plexus brachial.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Brachial plexus, Da Vinci robot, Phrenic nerve, Robot-assisted microsurgery, Telemicrosurgery

Mots clés : Plexus brachial, Robot Da Vinci, Nerf phrénique, Microchirurgie robotique, Télémicrochirurgie


Mappa


© 2014  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 33 - N° 5

P. 356-360 - ottobre 2014 Ritorno al numero
Articolo precedente Articolo precedente
  • Proximal interphalangeal joint arthroplasty with Neuflex® implants: Relevance of the volar approach and early rehabilitation
  • S. Bouacida, C. Lazerges, B. Coulet, M. Chammas
| Articolo seguente Articolo seguente
  • Radial artery pseudoaneurysm: A rare complication after arthroscopic treatment of a volar wrist ganglion in a hemophilia patient
  • C. Clerico, M. Benatar, C. Dumontier

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.