Abbonarsi

Use of an automatic recording system for CT doses: Evaluation of the impact of iterative reconstruction on radiation exposure in clinical practice - 03/03/15

Doi : 10.1016/j.diii.2014.11.014 
L.-A. Burckel a, , D. Defez b, P.F. Chaillot a, P. Douek c, L. Boussel a, c
a Service de radiologie, hôpital de la Croix-Rousse, 103, Grande-Rue-de-la-Croix-Rousse, 69004 Lyon, France 
b PSRPM Imagerie GH Sud, service de physique médicale et radioprotection, centre hospitalier Lyon Sud, Bat 3B–1er étage, 165, chemin du Grand-Revoyet, 69495 Pierre-Bénite, France 
c Inserm U1044, CREATIS, CNRS UMR5220, INSA-Lyon, université Lyon 1, service de radiologie, hôpital Louis-Pradel, 28, avenue du Doyen-Jean-Line, 69500 Bron, France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Objective

Despite the obligatory recording of doses administered to patients during CT scans, this data is not easily accessible. The objective of this study was to implement and validate a computerised automated dose-recording system for CT scans, for a single radiology department.

Material and methods

Every patient undergoing a CT scan in our department over a one-year period was included in the study. The CT scanner was upgraded after eight months (installation of iterative reconstruction and choice of an additional voltage of 100kV). The system recorded, from DICOM image headers, the patient data and technical acquisition parameters. The statistical analysis compared the dose length products (DLP) before and after the upgrade, and compared them with the diagnostic reference levels (DRL).

Results

Four thousand seven hundred and ninety-five CT scans were included (2141 before the upgrade and 2654 after). For all of the acquisition protocols tested, there was a reduction in DLP after the upgrade. The mean reduction was 30%, with a range of 17% to 44% depending on the protocol. After the upgrade, all of the mean DLPs were under the DRL thresholds (P<0.0001).

Conclusion

The proposed tool enabled systematic recording of the doses of radiation used in CT scans. It confirmed the significant reduction in the dose resulting from the implementation of iterative reconstruction, and enabled an exhaustive and rapid control of the respect of DRLs.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : CT scan, Iterative reconstruction, Dose, Medical computer application, Patient safety


Mappa


© 2014  Éditions françaises de radiologie. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 96 - N° 3

P. 265-272 - Marzo 2015 Ritorno al numero
Articolo precedente Articolo precedente
  • Liver iron overload assessment by MRI R2* relaxometry in highly transfused pediatric patients: An agreement and reproducibility study
  • S. Verlhac, M. Morel, F. Bernaudin, S. Béchet, C. Jung, M. Vasile
| Articolo seguente Articolo seguente
  • Ovarian tumors in children and adolescents: A series of 41 cases
  • E. Péroux, S. Franchi-Abella, D. Sainte-Croix, S. Canale, F. Gauthier, H. Martelli, D. Pariente, C. Adamsbaum

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.