Riassunto

Background

Recent pacing guidelines from the European Society of Cardiology recommend cardiac resynchronisation therapy (CRT) in patients with an atrioventricular (AV) nodal pacing indication and reduced ejection fraction (EF). However, concerns over added expenditure may limit its widespread implementation. We investigate the potential incremental cost of biventricular over right ventricular pacing if such a practice was adopted.

Methods

Retrospective analysis was performed of devices implanted over eight years. The database was analysed for device type, pacing indication and EF. Cost analysis was performed.

Results

1751 devices were implanted over eight years at an averaged cost of AUD$1,369,125 per year. 172 with CRT were excluded. 25.4 (11.6%) patients per year had an EF≤50% and AV nodal disease. 18.4 were in sinus rhythm (SR) and 7.0 in atrial fibrillation (AF). Of these, 13.5 (6.2%) had EF≤45% (9.9 SR, 3.6 AF) and 8.2 (3.8%) had EF≤35% (5.6 SR, 2.6 AF). Based on an incremental cost of $4,000 per device, if all patients with EF≤50% received CRT, the total cost increment per year equates to $73,500 for SR patients or $101,500 if AF patients were included. In patients with EF≤35% and EF≤45%, this amounts to $22,500 and $39,500 per year for SR patients respectively or $33,000 and $54,000 per year if AF patients were included. Depending on the EF and rhythm, this represents a 1.6% to 7.4% increase per year in the pacing budget for an increased patient population of between 2.6% (EF≤35% in SR) to 11.6% (EF≤50%).

Conclusion

A small proportion of additional patients will qualify for CRT based on the chosen cut-off and rhythm. Although the individual incremental cost for biventricular over right ventricular pacing is high in patients with AV nodal disease and reduced EF, overall this represents at most, a modest increase in the total pacing budget.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Cardiac resynchronisation therapy, Biventricular pacing, Right ventricular pacing, Atrioventricular nodal disease, Heart failure


Mappa


© 2014  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 24 - N° 4

P. 354-358 - aprile 2015 Ritorno al numero
Articolo precedente Articolo precedente
  • Risk Factors for Hospital Death in Patients With Acute Aortic Dissection
  • Jing Zhang, Yujuan Jiang, Chao Gao, Jun Feng, Ailing Wang
| Articolo seguente Articolo seguente
  • Copeptin (C-terminal pro Arginine-Vasopressin) is an Independent Long-Term Prognostic Marker in Heart Failure with Reduced Ejection Fraction
  • Zoltán Pozsonyi, Zsolt Förhécz, Tímea Gombos, István Karádi, Lívia Jánoskuti, Zoltán Prohászka

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.