Abbonarsi

Relationship between autologous bone graft osteointegration and correction loss after antero-posterior spondylodesis of traumatic vertebral body fracture - 01/04/15

Doi : 10.1016/j.otsr.2014.12.012 
D. Kubosch , L. Konstantinidis, P. Helwig, A. Hirschmüller, P.C. Strohm, N.P. Südkamp
 Klinikum der Albert-Ludwigs-Universität Freiburg, Department Orthopädie und Traumatologie, 79106 Freiburg im Breisgau, Germany 

Corresponding author. Department of Orthopedic and Trauma Surgery, Albert-Ludwigs-University of Freiburg, Medical Center, Hugstetterstr. 55, 79106 Freiburg im Breisgau, Germany. Tel.: +49 761 270 24010; fax: +49 761 270 24450.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background

A common method to restore the sagittal alignment and stabilize the spinal column is a dorso-ventral spondylodesis. It is assumed that correction loss after posttraumatic spondylodesis results from inadequate incorporation of the autologous iliac crest graft.

Materials and methods

Retrospective documentation of patients with unstable vertebral body fractures of the thoracic or lumbar spine with concomitant rupture of at least one adjacent intervertebral disk who received surgical treatment at our institution from 2000 to 2006. Followed by analysis of the computer tomography documentation of a total of 142 patients with unstable vertebral body fracture stabilized by posterior internal fixator and anterior iliac crest spondylodesis.

Results

The following mean angle changes were derived from the second series of CT scans performed on average 283 days after anterior spondylodesis: vertebral wedge angle (VWA): 2.1°; segmental kyphotic angle: 4.9°; adjusted-SKA: 4.8°; sagittal index (SI): −0.04; segmental-scoliotic-angle (SSA): 0°; adjusted-SSA: 0°. Changes in VWA, both SKAs and SI postoperatively and prior to ME, were statistically significant (P<0.05). The McAfee fusion assessment of the graft showed: full fusion: cranial 64%, caudal 47%; partial fusion: cranial 20.5%, caudal 29%; lysis: cranial 8.5%, caudal 17%; graft resorption: 7%. No correlation was found between the above-mentioned angle changes and fusions grade.

Discussion

The importance of radiological evidence of fusion deficiency is questionable, because the extent of fusion only has a minimal effect on correction loss.

Level of evidence

Level IV.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Spinal fusion, Spondylodesis, Bone graft, Correction loss


Mappa


© 2015  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 101 - N° 2

P. 221-225 - aprile 2015 Ritorno al numero
Articolo precedente Articolo precedente
  • Biomechanical study of dynamic changes in L4–L5 foramen surface area in flexion and extension after implantation of four interspinous process devices
  • C. Hirsch, C. Breque, S. Ragot, H. Pascal-Mousselard, J.-P. Richer, M. Scepi, F. Khiami
| Articolo seguente Articolo seguente
  • Short-segment posterior instrumentation combined with calcium sulfate cement vertebroplasty for thoracolumbar compression fractures: Radiographic outcomes including nonunion and other complications
  • B.X. Bu, M.J. Wang, W.F. Liu, Y.S. Wang, H.L. Tan

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.