Prospective ECG-gated high-pitch dual-source cardiac CT angiography in the diagnosis of congenital cardiovascular abnormalities: Radiation dose and diagnostic efficacy in a pediatric population - 11/05/17

Doi : 10.1016/j.diii.2016.03.014 
M. Koplay a, , O. Kizilca b, D. Cimen c, M. Sivri a, H. Erdogan a, O. Guvenc c, M. Oc d, B. Oran c
a Department of Radiology, Medical Faculty, Selcuk University, Konya, Turkey 
b Department of Radiology, Horasan Government Hospital, Erzurum, Turkey 
c Department of Pediatric Cardiology, Medical Faculty, Selcuk University, Konya, Turkey 
d Department of Cardiovascular Surgery, Medical Faculty, Selcuk University, Konya, Turkey 

Corresponding author at: Department of Radiology, Medical Faculty, Selcuk University, The Central Campus, 42075 Konya, Turkey.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Purpose

The goal of this study was to investigate the radiation dose and diagnostic efficacy of cardiac computed tomography angiography (CCTA) using prospective ECG-gated high-pitch dual-source computed tomography (DSCT) in the diagnosis of congenital cardiovascular abnormalities in pediatric population.

Materials and methods

One hundred five pediatric patients who were clinically diagnosed with congenital heart disease with suspected extracardiac vascular abnormalities were included in the study. All CCTAs were performed on a 128×2-section DSCT scanner. CCTA findings were compared with surgical and/or conventional cardiac angiography findings. Dose-length product (DLP) and effective doses (ED) were calculated for each patient. Patients were divided into 4 groups by age, and ED and DLP values were compared among groups. The image quality was evaluated using a five-point scale.

Results

CCTA showed 173 abnormalities in 105 patients. There were 2 patients with false positive and 3 with false negative findings. The sensitivity and specificity of CCTA were 98.3% and 99.9%, respectively. The positive predictive value and negative predictive value of CCT were 98.9% and 99.9%, respectively. The average DLP and ED values were 15.6±9.6 (SD) mGy.cm and 0.34±0.10 (SD) mSv, respectively. The mean image quality score was 4.8±0.5 (SD) in all patients. The inter-observer agreement for the image quality scores was good (κ=0.80).

Conclusion

CCTA is an excellent imaging modality for evaluation of cardiovascular abnormalities and provides excellent image quality with very low radiation exposure when low-dose prospective ECG-triggered high-pitch DSCT is used.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Cardiovascular, Congenital, Prospective ECG-triggered, Cardiac CT, Dual-source CT


Mappa


© 2016  Editions françaises de radiologie. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 97 - N° 11

P. 1141-1150 - Novembre 2016 Ritorno al numero
Articolo precedente Articolo precedente
  • Ultra-low-dose chest CT with iterative reconstruction does not alter anatomical image quality
  • F. Macri, J. Greffier, F.R. Pereira, C. Mandoul, E. Khasanova, G. Gualdi, J.P. Beregi
| Articolo seguente Articolo seguente
  • Correlation between primary flat foot and lower extremity rotational misalignment in adults
  • A. Cebulski-Delebarre, N. Boutry, C. Szymanski, C. Maynou, G. Lefebvre, E. Amzallag-Bellenger, A. Cotten

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.