Reverse shoulder arthroplasty for proximal humerus fractures: Is the glenoid implant problematic? - 27/09/18

Doi : 10.1016/j.otsr.2018.06.008 
Arthur Lignel a, , Julien Berhouet b, Marc-Alexandre Loirat a, Philippe Collin c, Hervé Thomazeau a, David Gallinet d, Pascal Boileau e, Luc Favard d
a CHU Pontchaillou, 35000 Rennes, France 
b CHU de Tours, 37000 Tours, France 
c CHP de Saint-Grégoire, 35760 Saint-Grégoire, France 
d Upper Limb Orthopedic Surgery University, 25000 Besançon, France 
e CHU de Nice, 06000 Nice, France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Introduction

Reverse shoulder arthroplasty (RSA) is a key tool in the orthopedic trauma surgeon's arsenal, especially when faced with a proximal humerus fracture in older patients. However, few studies have focused on the glenoid side of RSA in this indication as the implant is placed in a generally healthy scapula.

Hypothesis

Glenoid implants for RSA after trauma are well positioned and do not often cause complications.

Material and methods

Retrospective multicenter study of 513 patients who underwent RSA because of a proximal humerus fracture. The mean follow-up was 55 months. Radiographs were used to assess the height and tilt of the glenoid implant, along with the development of scapular notching or loosening. The clinical outcomes were determined based on the Constant score.

Results

At the last follow-up, 44% of shoulders had scapular notching, 7% of which were severe (stages 3–4). This notching was progressive, with two resulting in loosening. The rate of severe notching was higher in patients with a high glenoid implant (62.5% vs. 42.3%, p=0.03) or glenosphere with superior tilt (58.3% vs. 37.8%, p=0.02). Nine patients had confirmed loosening and 63 had potential loosening. This was more common in cases with superior tilt (9.3% vs. 0.4%, p<0.001). Patients with a high glenoid implant had a lower Constant score (57 vs. 45, p<0.001). There fewer cases of severe notching when a lateralized glenoid implant was used (0% vs. 7%, p<0.05) and/or the humeral implant had a smaller neck-shaft angle (implants<155°: 3% vs. implants at 155°: 8.5%, p=0.03).

Discussion and conclusion

Glenoid loosening and severe scapular notching are related to poor positioning and/or incorrect orientation of the glenosphere. Implant selection is important, as there is little to no notching when less-angled humeral implants and lateralized glenoid implants are used.

Level of evidence

IV.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Shoulder joint, Orthopedic Surgical Procedure, Traumatology, Joint Prosthesis


Mappa


© 2018  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 104 - N° 6

P. 773-777 - ottobre 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Accuracy of patient-specific guided implantation of the glenoid component in reversed shoulder arthroplasty
  • O. Verborgt, A.I. Hachem, K. Eid, K. Vuylsteke, M. Ferrand, P. Hardy
| Articolo seguente Articolo seguente
  • Reverse shoulder arthroplasty in recent proximal humerus fractures
  • Jean-David Werthel, François Sirveaux, Damien Block

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.