Abbonarsi

Artificial intelligence assistance for fetal head biometry: Assessment of automated measurement software - 19/12/18

Doi : 10.1016/j.diii.2018.08.001 
G. Ambroise Grandjean a, , G. Hossu b, C. Bertholdt c, P. Noble c, O. Morel b, G. Grangé c
a Inserm, IADI, université de Lorraine, 54500 Vandœuvre-lès-Nancy, France 
b Inserm, CIC, université de Lorraine, CHRU de Nancy, 54000 Nancy, France 
c Department of obstetrics, Port-Royal, hôpital Cochin, Assistance Publique–Hôpitaux de Paris, 75014 Paris, France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Purpose

To evaluate the feasibility and reproducibility of artificial intelligence software (Smartplanes®) to automatically identify the transthalamic plane from 3D ultrasound volumes and to measure the biparietal diameter (BPD) and head circumference (HC) in fetus.

Material and methods

Thirty fetuses were evaluated at 17–30 weeks’ gestation. For each fetus two three-dimensional (3D) volumes of the fetal head along with one conventional two-dimensional (2D) image of the transthalamic plane were prospectively acquired. The Smartplanes® software identified the transthalamic plane from the 3D volumes and performed BPD and HC measurements automatically (3D auto). Two experienced sonographers also measured BPD and HC from 2D images and from the 3D volumes. Measurements were compared using Bland-Altman plots. Interclass correlation coefficient (ICC) was used to evaluate intra- and interobserver reproducibility.

Results

For each series of measurements, intra- and interobserver reproducibility rates were high with ICC values>0.98. The 95% confidence intervals between the BPD measurements were 2mm (3D versus 2D) and 4mm (3D auto versus 2D) and the HC measurements were 7.5mm (3D versus 2D) and 11mm (3D auto versus 2D).

Conclusion

Fetal head measurements obtained automatically by Smartplanes® software from 3D volumes show good agreement with those obtained by two experienced sonographers from conventional 2D images and 3D volumes. The reproducibility of these measurements is similar to that observed by experienced sonographers.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Fetal biometry, Artificial intelligence (AI), Automatic measurement software, Agreement study, Reproducibility


Mappa


© 2018  Soci showét showé françaises de radiologie. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 99 - N° 11

P. 709-716 - novembre 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Breast mass characterization using shear wave elastography and ultrasound
  • S. Hari, S.B. Paul, R. Vidyasagar, E. Dhamija, A.D. Adarsh, S. Thulkar, S. Mathur, V. Sreenivas, S. Sharma, A. Srivastava, V. Seenu, R. Prashad
| Articolo seguente Articolo seguente
  • Transcatheter arterial embolization for iatrogenic bleeding after endoscopic ultrasound-guided pancreaticobiliary drainage
  • N.J. Lee, J.H. Shin, S.S. Lee, D.H. Park, S.K. Lee, H.-K. Yoon

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.