Abbonarsi

A Modified DWT-SVD Algorithm for T1-w Brain MR Images Contrast Enhancement - 20/07/19

Doi : 10.1016/j.irbm.2019.04.007 
M. Sahnoun a, , F. Kallel a, M. Dammak b, O. Kammoun c, C. Mhiri b, K. Ben Mahfoudh c, A. Ben Hamida a
a ATMS Lab, Advanced Technologies for Medicine and Signals, ENIS, Sfax University, Tunisia 
b Neurology Department, CHU, Sfax, Tunisia 
c Radiology Department, CHU, Sfax, Tunisia 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 9
Iconografia 6
Video 0
Altro 0

Abstract

Background

Image contrast enhancement is considered as the most useful technique permitting a better appearance of the low contrast images. This paper presents a modified Discret Wavelet Transform - Singular Value Decomposition (DWT-SVD) approach for the enhancement of low contrast Brain MR Images used for brain tissues exploration.

Methods

The proposed technique is processed as follows: first of all, we consider low contrast T1-weighted MRI slices as input images (A1) on which we apply General Histogram Equalization (GHE) algorithm to have equalized images referred as (A2) having zero as mean and one as variance. Secondly, by using the Discrete Wavelet Transform (DWT) algorithm, both (A1) and (A2) are divided into low and high frequency sub-bands. On the low frequency (LL1) and (LL2) sub-bands, SVD is processed in order to generate three matrix factorization (U, V and Σ) where the maximums of (U) and (V) matrix are used for the estimation of a correction coefficient (ξ). Our contribution in this paper is to estimate the new singular value matrix (New Σ) using a weighted sum of both original and equalized singular value matrix thanks to an adjustable parameter (μ) for the targeted low contrast images. This parameter, ranged between 0.05 and 0.95, is determined empirically according to the input low contrast image. Finally, the enhanced resulting image is easily reconstructed using the Inverse SVD (ISVD) and the Inverse DWT (IDWT) processes.

Results

The database considered in our research consisted of 120 MR brain images where T1-weighted MR brain modality are selected for the contrast enhancement process. Considering the qualitative results, our proposed contrast enhancement method have shown better distinction between brain tissues and have preserved all White Matter (WM), Gray Matter (GM) and Cerebro-Spinal Fluid (CSF) pixel edges. In fact, histogram plots of images enhanced by proposed method covered all the gray level intensities. For the quantitative results, proposed method gives the highest PSNR, QRCM, SSIM, FSIM and EME values and the lowest AMBE values for (μ) equal to 0.65 as comparing to the rest of methods. These results signifies that proposed contrast enhancement method have provided greater image quality with preservation of image structure, feature and brightness.

Conclusion

Proposed method improved performance of contrast enhancement image without creating unwanted artifact and without destroying image edge information or affecting the specificities of brain tissues. This is due to the use of an empirically (μ) parameter adjustable according to the input MR images. Hence, the proposed approach is appropriate for enhancing contrast of huge type of low contrast images.

Il testo completo di questo articolo è disponibile in PDF.

Graphical abstract

Il testo completo di questo articolo è disponibile in PDF.

Highlights

In this paper, a modified DWT-SVD method is proposed.
Proposed method is used for the enhancement of low contrast T1-w brain MR images.
The use of an adjustable singular value matrix equation proves better results.
Proposed method performs very efficiently in all types of low contrast images.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Low contrast brain MRI, T1-w modality, Contrast enhancement, DWT-SVD


Mappa


© 2019  AGBM. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 40 - N° 4

P. 235-243 - agosto 2019 Ritorno al numero
Articolo precedente Articolo precedente
  • High-Intensity Focused Ultrasound Using a Toroidal Transducer as an Adjuvant Treatment for Placenta Accreta: A Preliminary Ex Vivo Study
  • J. Caloone, V. Barrere, M. Sanchez, S. Cambronero, C. Huissoud, D. Melodelima
| Articolo seguente Articolo seguente
  • Proposing a Radial Basis Function and CSDM Indices to Predict the Traumatic Brain Injury Risk
  • J. Afshari, M. Haghpanahi, R. Kalantarinejad, M.M. Tafarroj

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.