Abbonarsi

Basic morphological characteristics of coracoid grafts obtained by open and arthroscopic Latarjet techniques: A comparative study - 23/09/20

Doi : 10.1016/j.otsr.2020.04.014 
Alvaro Minuesa-Asensio a, Francisco García-Esteo b, José Ramón Mérida-Velasco c, Carmen Barrio-Asensio c, Crótida de la Cuadra-Blanco c, Jorge Murillo-González c,
a Head of Service of the Hospital Fraternidad-Muprespa, Madrid, Spain 
b Service of Traumatology, Jiménez Díaz Foundation, Madrid, Spain 
c Department of Anatomy and Embryology, Faculty of Medicine, Complutense University of Madrid, 28040 Madrid, Spain 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background

A knowledge of the anthropometric characteristics of the coracoid graft (CG) that can be obtained by the open and arthroscopic Latarjet techniques may be beneficial in the preoperative planning and intraoperative decision making for coracoid osteotomy and transfer. We have not found any study that compared the morphology of the CG that can be obtained from open and arthroscopic Latarjet techniques. The purpose of this study was to verify if the basic anthropometric characteristics of CGs are equivalent.

Hypothesis

We hypothesize that the basic anthropometric characteristics of the CGs are similar.

Methods

Twenty fresh-frozen human paired cadaveric shoulder specimens that had been randomly distributed in two groups of 10 specimens each were used. Two surgeons, each with experience in performing the open and arthroscopic Latarjet technique, performed these procedures in each of the respective groups (OG, open group; AG, arthroscopic group). A CT scan was performed. Using the volume rendering technique, a metric analysis of the volume, area and length of the CG were performed, evaluated and statistically analysed.

Results

There were no significant differences in length (p=0.162) (mean length, 22.6mm for OG and 23.6mm for AG). There were significant differences in the volume (p=0.031) and area (p=0.007) of the CG, being lower in the OG (mean volume, 2.8 cm3 for OG and 3.6 cm3 for AG; mean area, 9.9 cm2 for OG and 12.8 cm2 for AG). No significant differences were observed by sex or laterality.

Conclusion

The mean lengths of the CGs that were obtained by each technique are equivalent. However, the areas and volumes of the grafts are different, being lower in the open surgery. These differences have not been an impediment to perform the technique. Our results corroborates that consolidation is more related to the preparation and placement than to the anthropometric characteristics of the CG. No significant differences were observed by sex or laterality.

Level of evidence

Basic Science.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Shoulder, Instability, Open Latarjet, Arthroscopic, Technique, Coracoid graft, Morphologic characteristics


Mappa


© 2020  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 106 - N° 6

P. 1083-1087 - ottobre 2020 Ritorno al numero
Articolo precedente Articolo precedente
  • Isokinetic evaluation of the shoulder and elbow after Latarjet procedure
  • Eduardo A. Malavolta, Diego G. Cruz, Mauro Emilio Conforto Gracitelli, Jorge H. Assunção, Fernando B. Andrade-Silva, Felix R. Andrusaitis, Arnaldo A. Ferreira Neto
| Articolo seguente Articolo seguente
  • Mechanical behavior of screw versus Endobutton for coracoid bone-block fixation
  • Vadim Azoulay, Jérôme Briot, Pierre Mansat, Pascal Swider, Nicolas Bonnevialle

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.