Abbonarsi

Diagnostic performance of different sampling approaches for SARS-CoV-2 RT-PCR testing: a systematic review and meta-analysis - 25/08/21

Doi : 10.1016/S1473-3099(21)00146-8 
Nicole Ngai Yung Tsang, MPH a, Hau Chi So, MNurs a, Ka Yan Ng, MPH a, Benjamin J Cowling, ProfPhD a, Gabriel M Leung, ProfMD a, Dennis Kai Ming Ip, MD a, ⁎
a WHO Collaborating Centre for Infectious Disease Epidemiology and Control, School of Public Health, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China 

* Correspondence to: Dr Dennis Kai Ming Ip, WHO Collaborating Centre for Infectious Disease Epidemiology and Control, School of Public Health, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, 999077, China WHO Collaborating Centre for Infectious Disease Epidemiology and Control School of Public Health Li Ka Shing Faculty of Medicine The University of Hong Kong Hong Kong Special Administrative Region 999077 China

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Summary

Background

The comparative performance of different clinical sampling methods for diagnosis of SARS-CoV-2 infection by RT-PCR among populations with suspected infection remains unclear. This meta-analysis aims to systematically compare the diagnostic performance of different clinical specimen collection methods.

Methods

In this systematic review and meta-analysis, we systematically searched PubMed, Embase, MEDLINE, Web of Science, medRxiv, bioRxiv, SSRN, and Research Square from Jan 1, 2000, to Nov 16, 2020. We included original clinical studies that examined the performance of nasopharyngeal swabs and any additional respiratory specimens for the diagnosis of SARS-CoV-2 infection among individuals presenting in ambulatory care. Studies without data on paired samples, or those that only examined different samples from confirmed SARS-CoV-2 cases were not useful for examining diagnostic performance of a test and were excluded. Diagnostic performance, including sensitivity, specificity, positive predictive value, and negative predictive value, was examined using random effects models and double arcsine transformation.

Findings

Of the 5577 studies identified in our search, 23 studies including 7973 participants with 16 762 respiratory samples were included. Respiratory specimens examined in these studies included 7973 nasopharyngeal swabs, 1622 nasal swabs, 6110 saliva samples, 338 throat swabs, and 719 pooled nasal and throat swabs. Using nasopharyngeal swabs as the gold standard, pooled nasal and throat swabs gave the highest sensitivity of 97% (95% CI 93–100), whereas lower sensitivities were achieved by saliva (85%, 75–93) and nasal swabs (86%, 77–93) and a much lower sensitivity by throat swabs (68%, 35–94). A comparably high positive predictive value was obtained by pooled nasal and throat (97%, 90–100) and nasal swabs (96%, 87–100) and a slightly lower positive predictive value by saliva (93%, 88–97). Throat swabs have the lowest positive predictive value of 75% (95% CI 45–96). Comparably high specificities (range 97–99%) and negative predictive value (range 95–99%) were observed among different clinical specimens. Comparison between health-care-worker collection and self-collection for pooled nasal and throat swabs and nasal swabs showed comparable diagnostic performance. No significant heterogeneity was observed in the analysis of pooled nasal and throat swabs and throat swabs, whereas moderate to substantial heterogeneity (I2 ≥30%) was observed in studies on saliva and nasal swabs.

Interpretation

Our review suggests that, compared with the gold standard of nasopharyngeal swabs, pooled nasal and throat swabs offered the best diagnostic performance of the alternative sampling approaches for diagnosis of SARS-CoV-2 infection in ambulatory care. Saliva and nasal swabs gave comparable and very good diagnostic performance and are clinically acceptable alternative specimen collection methods. Throat swabs gave a much lower sensitivity and positive predictive value and should not be recommended. Self-collection for pooled nasal and throat swabs and nasal swabs was not associated with any significant impairment of diagnostic accuracy. Our results also provide a useful reference framework for the proper interpretation of SARS-CoV-2 testing results using different clinical specimens.

Funding

Hong Kong Research Grants Council.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2021  Elsevier Ltd. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 21 - N° 9

P. 1233-1245 - settembre 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • An imaginary pandemic and its consequences
  • Sanjeet Bagcchi
| Articolo seguente Articolo seguente
  • Genomic characteristics and clinical effect of the emergent SARS-CoV-2 B.1.1.7 lineage in London, UK: a whole-genome sequencing and hospital-based cohort study
  • Dan Frampton, Tommy Rampling, Aidan Cross, Heather Bailey, Judith Heaney, Matthew Byott, Rebecca Scott, Rebecca Sconza, Joseph Price, Marios Margaritis, Malin Bergstrom, Moira J Spyer, Patricia B Miralhes, Paul Grant, Stuart Kirk, Chris Valerio, Zaheer Mangera, Thaventhran Prabhahar, Jeronimo Moreno-Cuesta, Nish Arulkumaran, Mervyn Singer, Gee Yen Shin, Emilie Sanchez, Stavroula M Paraskevopoulou, Deenan Pillay, Rachel A McKendry, Mariyam Mirfenderesky, Catherine F Houlihan, Eleni Nastouli

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.