Abbonarsi

Reliability assessment of cervical spine parameters measured on full-body radiographs in asymptomatic subjects and patients with spinal deformity - 29/10/21

Doi : 10.1016/j.otsr.2021.103026 
Michel Salameh, Aren Joe Bizdikian, Eddy Saad, Renée Maria Saliby, Rhéa Nacouzi, Nour Khalil, Ismat Ghanem, Gaby Kreichati, Ayman Assi
 Laboratory of Biomechanics and Medical Imaging, Faculty of Medicine, University of Saint-Joseph, Damascus Street, Beirut, Lebanon 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background

Cervical spinal alignment is usually assessed on full-body radiographs allowing for the concomitant evaluation of possible compensatory mechanisms that may occur at any level in the setting of postural malalignment.

Hypothesis

Cervical parameters measured on full-body radiographs are reliable.

Patients and methods

A total of 70 subjects were included and divided in 3 groups: asymptomatic adults (n=21), adolescents with idiopathic scoliosis (n=20), and adults with spinal deformity (n=29), for whom full-body low-dose biplanar radiographs were obtained. Eighteen cervical parameters including gaze and cervical curvature, upper cervical spine, global cervical alignment, thoraco-cervical and cervico-pelvic parameters were measured by 4 operators, three times each. The intraclass correlation coefficient (ICC) and the 95% confidence interval (95% CI) where calculated for each parameter and compared between the 3 groups.

Results

ICC and the 95% CI were similar between the 3 groups. The measured parameters showed a very high repeatability (ICC>0.8) except for C0-C2, which presented an average repeatability (ICC=0.57). The cSVA, CTPA, C2-SPi, cranial offset, T1-SPi, CBVA and cranial tilt had a 95% CI<2 (° or cm). The TIA, T1-CL and C0-C2 had a 95% CI>6°.

Discussion

The poor visibility of the foramen magnum, hard palate, C7, T1, and the sternum on radiographs could explain why certain parameters showed a higher measurement error. The assessment of these error margins is essential for an accurate evaluation of cervical spinal deformities and a proper therapeutic approach.

Level of evidence

III; retrospective analysis of prospectively collected data.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Cervical spine, Measurement error, Reliability, Sagittal alignment, Full-body radiographs


Mappa

Patients and methods

© 2021  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 107 - N° 7

Articolo 103026- novembre 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • Sagittal reduction of spinal deformity: Superior versus lateral screw-rod connection
  • Solène Prost, Sébastien Pesenti, Kaissar Farah, Patrick Tropiano, Stéphane Fuentes, Benjamin Blondel
| Articolo seguente Articolo seguente
  • Performance of Forward Roll Maneuvers Following Corrective Spinal Fusion for Idiopathic Scoliosis Patients
  • Takahiro Iida, Jyunya Katayanagi, Akihisa Ato, Kazuyuki Matsumoto, Atsuki Hayamizu, Hirokazu Furukawa, Takashi Tobinaga, Makoto Yazawa, Chieko Miyazaki, Satoru Ozeki

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.