Cementless cups do not increase osteolysis risk in metal-on-metal total hip arthroplasty - 06/11/09

Doi : 10.1016/j.otsr.2009.07.007 
J. Beldame a, F. Carreras a, b, P. Oger a, , P. Beaufils a
a Orthopaedics and Traumatology Department, Versailles Hospital Center, 177, rue de Versailles, 78150 Le-Chesnay, France 
b Servicio de Cirugía de Cadera y Rodilla, Departamento de Ortopedia y Traumatología, Hospital Militar Central “Cir My Dr. Cosme Argerich”, avenue Luis María Campos 726, Buenos Aires, Argentina 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Summary

Background

Metal-on-metal bearings in total hip arthroplasty (THA) were introduced to reduce the production of wear debris and debris-induced periprosthetic osteolysis. Analysis of various series according to the type of selected acetabular fixation highlights different evolutions: favourable results with uncemented cups contrasting with loosening and radiolucent lines (RLL) evolution for cemented cups.

Hypothesis

Combining metal-on-metal bearings to uncemented cups does not increase the osteolysis risk at a minimum 5 years’ follow-up.

Materials and methods

From January 1999 to December 2002, 106 Metasul™ THAs were implanted in 95 patients using a Hardinge anterolateral approach (40 women and 55 men with an average age of 59.2 years). The cups were of cementless, hydroxyapatite-coated Cedior™ type (Zimmer) housing a Metasul™ insert in a polyethylene sandwich. The femoral stem used was the cemented Acora™, then the Exafit™ (Zimmer) type with Metasul™ 28-mm head mounted on a 8/10 Morse taper. Patients were evaluated clinically using the Postel-Merle-d’Aubigné (PMA) scoring system and radiologically using various markers: cup inclination angle, eventual RLL presence, appearance of osteolysis images, ectopic ossifications and finally, eventual implant migration. In the eventuality of suspected RLL evolution or osteolysis, advanced imaging was performed; joint aspiration liquid and cobalt serum level were studied.

Results

We reviewed 94 prostheses (85 patients) with an average follow-up of 6.4 years (4.3 to 9.3 years, median of 6.3 years). The rate of patient loss from follow-up and death was 12.1%. The PMA score of non-revised patients increased from 11.4±1.5 to 17.6±0.2 at follow-up. We numbered ten re-operations not attributable to the type of bearings used. Three revisions were directly related to the metal-on-metal bearing: two metallosis due to impingement and one case of hypersensitivity. Cup inclination angle was 45.7±5.49°. No implant migration was noted during the follow-up duration. Only one cup undergoing revision presented a substantial osteolysis. On the femoral side, with non-revised implants, we observed 13 cement/bone RLL images around nine femoral stems and six calcar resorptions. The survival rate at more than 6 years was 95.8% (91.8–99.8) for the cups and 94.8% (90.3–99.2) for the femoral stems (95% confidence interval).

Discussion

The present study confirms our hypothesis: with Metasul™ bearings equipped cementless cups, the rates of aseptic loosening, RLL or acetabular osteolysis are low and remain stable over time, unlike the results observed for Metasul™ series with polyethylene directly cemented on bone. Specific complications, such as metallosis due to impingement and hypersensitivity, can rarely be encountered. These results encourage us to continue employing metal-on-metal bearings with non-cemented cups in active patients.

Level of evidence

Level IV: Therapeutic study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Total hip arthroplasty, Metal-on-metal bearings, Osteolysis


Mappa


© 2009  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 95 - N° 7

P. 478-490 - novembre 2009 Ritorno al numero
Articolo precedente Articolo precedente
  • Assessment of a percutaneous iliosacral screw insertion simulator
  • J. Tonetti, L. Vadcard, P. Girard, M. Dubois, P. Merloz, J. Troccaz
| Articolo seguente Articolo seguente
  • Total hip arthroplasty in severe segmental femoral bone loss situations: Use of a reconstruction modular stem design (JVC IX™)
  • A. Bertani, M. Helix, M.L. Louis, A. Rochwerger, G. Curvale

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.