Abbonarsi

Prospective, randomized study of conventional versus HybridKnife endoscopic submucosal dissection methods for the esophagus: an animal study - 11/08/11

Doi : 10.1016/j.gie.2010.12.004 
Norio Fukami, MD , a, Chang Beom Ryu, MD a, Sherif Said, MD b, Zachary Weber, MD b, Yang K. Chen, MD a,
a Division of Gastroenterology and Hepatology, University of Colorado Denver, Aurora, Colorado, USA 
b Department of Pathology, University of Colorado Denver, Aurora, Colorado, USA 

Reprint requests: Norio Fukami, MD, Division of Gastroenterology and Hepatology, University of Colorado Denver, Mail Stop F735, AOP, 1635 Aurora Court, Room 2.031, Aurora, CO 80045-2541

Riassunto

Background

Endoscopic submucosal dissection (ESD) increases en bloc and histologically complete resection rate of neoplastic mucosal tumors but is technically more demanding than EMR. Limited data are available comparing the efficacy and safety of a new ESD designed to overcome these limitations and conventional ESD (C-ESD) techniques.

Objective

To compare the safety, efficacy, and operation time of the new HybridKnife ESD (HK-ESD) with C-ESD in the esophagus.

Design

Prospective, randomized, controlled study.

Setting

Animal research laboratory.

Subjects

Seventeen anesthetized Yorkshire pigs.

Interventions

Removal of a 4-cm length of half-circumference esophageal mucosa by C-ESD with Hook knife or Flexknife versus HK-ESD.

Main Outcome Measurements

Procedure time, en bloc and complete resection rate, and complications (bleeding and perforation).

Results

All resections were completed en bloc. Procedure time was shorter in C-ESD. However, it was similar after 12 procedures. Significantly more bleeding occurred during C-ESD (28 vs 12, P = .0007). Histological muscularis propria injuries occurred with equal frequency (16 vs 17) and were mostly seen during the first 11 procedures. There were 3 perforations (2 endoscopic, 1 histological), all with C-ESD.

Limitations

Nonsurvival study, use of 2 conventional knives, no training period for a new procedure.

Conclusions

The HK-ESD technique was equally effective as the C-ESD technique for successful en bloc resection and was safer with less bleeding and perforation. Although procedure time was longer in HK-ESD, the difference became nonsignificant after 12 procedures.

Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : C-ESD, ESD, HK-ESD, MP


Mappa


 DISCLOSURE: Equipment and devices used in this study were provided by ERBE and Olympus Corporation. All authors disclosed no financial relationships relevant to this publication.


© 2011  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 73 - N° 6

P. 1246-1253 - giugno 2011 Ritorno al numero
Articolo precedente Articolo precedente
  • Bowel preparation with split-dose polyethylene glycol before colonoscopy: a meta-analysis of randomized controlled trials
  • Todd W. Kilgore, Abdillahi A. Abdinoor, Nicholas M. Szary, Samuel W. Schowengerdt, Jamie B. Yust, Abhishek Choudhary, Michelle L. Matteson, Srinivas R. Puli, John B. Marshall, Matthew L. Bechtold
| Articolo seguente Articolo seguente
  • Continuing Medical Education Exam: June 2011
  • Raquel E. Davila, Jeffrey H. Lee, William Ross, Shou-Jiang Tang, G.S. Raju, Glenn M. Eisen

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.