Abbonarsi

Retrieval analysis of squeaking ceramic implants: Are there related specific features? - 25/04/12

Doi : 10.1016/j.otsr.2011.12.003 
C. Chevillotte a, , b , R.T. Trousdale c , K.-N. An d , D. Padgett e , T. Wright e
a T-Pavilion, Department of Orthopaedic Surgery, Edouard-Herriot Hospital, 5, place d’Arsonval, 69437, Lyon cedex 03, France 
b Shocks Biomechanics Research Laboratory, LBMC-INRETS URMT 9406, Claude-Bernard University, Lyon, France 
c Department of Orthopedic surgery, Mayo Clinic, 200, First Street SW, 55902 Rochester, MN, USA 
d Biomechanic laboratory, Mayo Clinic, 200, First street, 55902 Rochester, MN, USA 
e Hospital for Special Surgery, 535, East 70th Street, 10021 New York, USA 

Corresponding author. Tel.: +33 4 72 11 76 33.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Summary

Introduction

Ceramic-on-ceramic total hip arthroplasty is routinely used for young and active patients with end stage of hip osteoarthritis. However, squeaking noise is a recently identified problem with such bearing surface. Many in vivo and in vitro studies have been conducted trying to find the potential causes of this phenomenon. However, we are not aware of any study analyzing retrieved ceramic implants for squeaking.

Hypothesis

Our primary hypothesis was that the surface analysis of retrieved ceramic implants with squeaking would present interesting deteriorations that could explain the squeaking noise.

Materials and methods

Nine retrieved squeaking implants from ceramic-on-ceramic total hip arthroplasty that were retrieved for various reasons (two exclusively for squeaking, four for recurrent dislocation, one for aseptic loosening and two for instability) were analyzed. Implant positioning was calculated, macroscopic damages were noticed and microscopic roughness was analyzed. The retrieved implants were then tested on a hip simulator reproducing flexion/extension motions in several situations in lubricated and non-lubricated conditions in order to reproduce squeaking.

Results

Five cups were considered with borderline insufficient anteversion. Gross impingement damage was visible on seven implants. All the retrieved heads had visible metal transfer on their surface. Eight implants had visible stripe wear. Microscopic analysis showed roughness higher than six microns on the retrieved heads. Squeaking was reproduced in vitro in dry conditions. In lubricated conditions, squeaking did not occur for the retrieved hips.

Discussion

This retrieval analysis suggests that problems of cup orientation and design which can lead to impingement can generate lubrication problems because of metal transfer plus/minus stripe wear which is a common theme in ceramic-on-ceramic bearings that squeak.

Level of evidence

Level IV, retrospective study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Squeaking, Total hip arthroplasty, Ceramic, Surface bearing, Metal transfer, Stripe wear


Mappa


© 2012  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 98 - N° 3

P. 281-287 - maggio 2012 Ritorno al numero
Articolo precedente Articolo precedente
  • Joint perception after hip or knee replacement surgery
  • M. Collins, M. Lavigne, J. Girard, P.-A. Vendittoli
| Articolo seguente Articolo seguente
  • Proximal femoral nail antirotation (PFN-ATM) fixation of extra-capsular proximal femoral fractures in the elderly: Retrospective study in 102 patients
  • E. Soucanye de Landevoisin, A. Bertani, P. Candoni, C. Charpail, E. Demortiere

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.