Abbonarsi

MRI versus histological methods for time course monitoring of steatosis amount in a murine model of NAFLD - 07/09/15

Doi : 10.1016/j.diii.2015.03.006 
L.-M. Leiber a, , J. Boursier b , S. Michalak c , V. Roullier d , L. Fizanne e , J. Chaigneau e , J. Roux e , V. Moal f , M. Flamment g , P. Bazeries a , P.-H. Ducluzeau h , C. Aube b
a Department of Radiology, LUNAM université, CHU Angers, 4, rue Larrey, 49000 Angers, France 
b Department of Hepatology, Laboratory HIFIH, UPRES 3859, LUNAM université, CHU Angers, 4, rue Larrey, 49000 Angers, France 
c Department of Pathology, LUNAM université, CHU Angers, 4, rue Larrey, 49000 Angers, France 
d LISA – laboratoire d’ingénierie des systèmes automatisés, LUNAM université, 62, avenue Notre-Dame-du-Lac, 49000 Angers, France 
e Laboratory HIFIH, UPRES 3859, LUNAM université, 4, rue Larrey, 49000 Angers, France 
f Department of Biology, Laboratory HIFIH, UPRES 3859, LUNAM université, CHU Angers, 4, rue Larrey, 49000 Angers, France 
g Inserm, UMR-S 872, centre de recherches des Cordeliers, rue de l’École-de-Médecine, 75006 Paris, France 
h Department of Endocrinology, LUNAM université, CHU Angers, 4, rue Larrey, 49000 Angers, France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Purpose

Hepatic steatosis is an increasingly frequent disease with potentially severe complications. A simple quantification method is required for pretherapeutic studies to allow steatosis monitoring. This study aimed at evaluating steatosis quantification via a standard 1.5T MRI machine in a murine model.

Materials and methods

Eleven groups of two rats received a choline methionine deficient diet. MRI was performed at days 0, 2, 4, 5, 6, 7 and 8, and weeks 2, 3, 4 and 5. A phased array surface coil system was used to acquire a GE T1 in- and out-of-phase multi-echo sequence, with neither cardiac nor respiratory synchronization. Steatosis was calculated with the 3-echoes method. Histological quantifications were performed both by optical analysis (percentage of fatty hepatocytes) and by automated measurement of the area of steatosis (AOS). The reference was total intrahepatic triglycerides (TIT). Protocol was approved by the ethic committee.

Results

Steatosis without inflammation, increasing with diet duration, was obtained. MRI provided better agreement (intraclass correlation coefficient) with TIT (0.889, p<0.001) than did AOS (0.629, p=0.001) or optical analysis (0.280, p=0.098). MRI permitted closer monitoring of TIT over time than did AOS or optical analysis. By multivariate analysis, MRI was an independent predictor of TIT on first step and ALT on second step. A model combining these 2 variables provided excellent agreement with TIT (0.953, p<0.001) and permitted excellent monitoring of steatosis over time.

Conclusion

MRI is reliable, easy, fast and superior to histological techniques for the assessment of hepatic steatosis in a murine model.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Magnetic resonance imaging, Animal model, Fatty liver, Histology, Quantification


Mappa


© 2015  Éditions françaises de radiologie. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 96 - N° 9

P. 915-922 - settembre 2015 Ritorno al numero
Articolo precedente Articolo precedente
  • Imaging features of lower limb malformations above the foot
  • A. Bergère, E. Amzallag-Bellenger, G. Lefebvre, A. Dieux-Coeslier, A. Mezel, B. Herbaux, N. Boutry
| Articolo seguente Articolo seguente
  • Characteristics of undetected prostate cancer on diffusion-weighted MR Imaging at 3-Tesla with a b-value of 2000 s/mm2: Imaging-pathologic correlation
  • M. Barral, F. Cornud, Y. Neuzillet, E. Lonchampt, L. Lassalle, N.B. Delonchamp, A. Scherrer

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.