Abbonarsi

Characteristics of undetected prostate cancer on diffusion-weighted MR Imaging at 3-Tesla with a b-value of 2000 s/mm2: Imaging-pathologic correlation - 07/09/15

Doi : 10.1016/j.diii.2015.03.004 
M. Barral a, , F. Cornud b, Y. Neuzillet c, E. Lonchampt d, L. Lassalle a, N.B. Delonchamp e, A. Scherrer a
a Department of Body Imaging, université de Versailles Saint-Quentin-en-Yvelines, hôpital Foch, 40, rue Worth, 92150 Suresnes, France 
b Department of Radiology A, université Paris-Descartes, hôpital Cochin, AP–HP, 75014 Paris, France 
c Department of Urology, université de Versailles Saint-Quentin-en-Yvelines, hôpital Foch, 92150 Suresnes, France 
d Department of Pathology, université de Versailles Saint-Quentin-en-Yvelines, hôpital Foch, 92150 Suresnes, France 
e Department of Urology, université Paris-Descartes, hôpital Cochin, AP–HP, 75014 Paris, France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Objective

To assess the accuracy of Diffusion-Weighted MR Imaging (DW-MRI) at 3-Teslas (3T) with a b-value of 2000s/mm2 (b-2000 DW-MRI) to detect prostate cancer (PCa) and to describe the histological features of missed tumors.

Methods

Prior to radical prostatectomy, 35 patients with a mean age of 64±6.2years old [51–77years old] had a b-2000 DW-MRI at 3-T, without rectal coil (acquisition time: 2min, 15s), and were analysed on an eight-sector basis by two independent readers blinded to the rest of the multiparametric-MRI protocol. Pathological tumor foci were matched with high intensity focal areas on MRI and correlated for Gleason score, sector location and largest axial diameter.

Results

Of the 280 sectors analysed, histology showed PCa in 113 (113/280, 40%). Overall DW-MRI sensitivity, specificity and accuracy for tumor detection were 79–81%, 99–95% and 92–82% for readers 1 and 2, respectively (kappa test: 0.78). Of all, 28 (28/113, 25%) and 22 (22/113, 20%) tumor foci were not detected by reader 1 and 2 respectively. These undetected tumor foci had a mean pathological axial axis of 5mm (range: 3–15mm) and a Gleason score of 6, 7 (3+4), 7 (4+3) and>7 in 15/28 (54%), 9/28 (32%), 3/28 (10%) and 1/28 (4%) of cases for reader 1, and in 11 (50%), 5 (23%), 5 (23%) and 1 (4%) of cases for reader 2.

Conclusion

A normal b-2000 DW-MRI at 3-T may miss small tumors without or with a minor Gleason 4 component.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Diffusion-weighted MR imaging, MR imaging, Ultra-high b-value, Prostate imaging, Prostate cancer


Mappa


© 2015  Éditions françaises de radiologie. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 96 - N° 9

P. 923-929 - Settembre 2015 Ritorno al numero
Articolo precedente Articolo precedente
  • MRI versus histological methods for time course monitoring of steatosis amount in a murine model of NAFLD
  • L.-M. Leiber, J. Boursier, S. Michalak, V. Roullier, L. Fizanne, J. Chaigneau, J. Roux, V. Moal, M. Flamment, P. Bazeries, P.-H. Ducluzeau, C. Aube
| Articolo seguente Articolo seguente
  • Breast tomosynthesis: Dosimetry and image quality assessment on phantom
  • E. Meyblum, F. Gardavaud, T.-H. Dao, V. Fournier, P. Beaussart, F. Pigneur, L. Baranes, A. Rahmouni, A. Luciani

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.